Premature failure of an insulating glass unit (IGU) is often due to a rapid permeation of moisture through the edge seal and into the air gap of the unit. The reasons for premature failure investigated by BRE are numerous; these often originate with difficult conditions on building sites.
Glazing of units in factories offers the potential for higher quality work - BRE has developed good practice guidance to maximise the benefits of factory glazing. The guidance, prepared as this two-part Digest, is based on research and good practice. Part 1 introduces the subject and describes the types of insulating glazing units and production facilities.
This part (Part 2) describes the packaging, transportation to site and storage of IGUs; their installation, protection in service and maintenance; and performance testing and monitoring.
| Edition : | 05 |
| File Size : | 1 file , 820 KB |
| Number of Pages : | 9 |
| Published : | 11/16/2005 |