Introduction

The purpose of a VAD is to visually alert people within a building that there is a fire emergency. The primary means of giving warning of fire in a building is an audible alarm signal (from a bell or electronic sounder) or a verbal message (from a voice alarm system). However, in many buildings the audible message needs to be supplemented by a visual alarm signal, eg as a means of giving warning to deaf and hard-of-hearing people, in areas of high ambient noise, in operating theatres or in broadcasting studios.

BS EN 54-23 categorises VADs in terms of ceiling, wall and open-class devices; these categories define a volume within which a minimum light level is required to warn those in the vicinity of the device. All categories are intended to illuminate a space such that, at the boundaries, a minimum illumination of 0.4 lux is met. There is no doubt that this requirement will demand a greater performance from VADs when compared with beacons and strobes currently on the market, for which there is no existing British or European standard. It will also result in increases in the demand of the loop supply current from a fire alarm control panel. However, this can be reduced by designing devices specifically for certain applications and optimising the performance accordingly.

The coverage volume test from BS EN 54-23 is used to measure the light output from VADs at a selection of evenly distributed points representative of the volume that they are intended to cover. Limitations in terms of distances for coverage are dependent on the specific directions and angles and indicate the points at which the minimum light level is achieved. As the distances are dependent on the measured effective luminous intensity, it is important to consider how this is calculated and how variables such as pulse type, duration and shape contribute to the effective luminous intensity.


Edition : 13
File Size : 1 file , 830 KB
Number of Pages : 12
Published : 01/01/2013

History


Related products

BRE IP10/02
Published Date: 08/22/2002
Metal cladding: assessing the thermal performance of built-up systems which use 'Z' spacers
$5.4
BRE AP68
Published Date: 01/01/1991
Daylight protractors
$17.7
BRE IP15/89
Published Date: 01/01/1989
Electromagnetic compatibility of building services: towards a European standard
$4.5
BRE AP281
Published Date: 01/01/2016
BRE Good Building Guides and Good Repair Guides A library of information for all construction professionals
$81.9

Best-Selling Products

NFSI B101.0-2017
Published Date: 01/11/2017
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.0-2021
Published Date: 03/12/2021
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.1-2009
Published Date: 10/13/2009
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.1-2020
Published Date: 2020
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.2-2020
Published Date: 2020
Test Method for Determining the Impact on Wet Coefficients of Friction of Various Chemical or Physical Walkway Surface Cleaners and Treatments on Common Hard-Surface Flooring Materials
$18
NFSI B101.3-2012
Published Date: 01/18/2012
Test Method for Measuring Wet DCOF of Common Hard-Surface Floor Materials
$18