AAMI 13958:2014 PDF

AAMI 13958:2014 PDF

Name:
AAMI 13958:2014 PDF

Published Date:
08/15/2014

Status:
[ Withdrawn ]

Description:

Concentrates for hemodialysis and related therapies

Publisher:
Association for the Advancement of Medical Instrumentation

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
aami-13958-2014_1884807

Choose Document Language:
0
Need Help?
This International Standard specifies minimum requirements for concentrates used for hemodialysis and related therapies. For the purpose of this International Standard, "concentrates" are a mixture of chemicals and water, or chemicals in the form of dry powder or other highly concentrated media, that are delivered to the end user to make dialysis fluid used to perform hemodialysis and related therapies. This International Standard is addressed to the manufacturer of such concentrates. In several instances in this International Standard, it became necessary to address the dialysis fluid, which is made by the end user, to help clarify the requirements for manufacturing concentrates. Because the manufacturer of the concentrate does not have control over the final dialysis fluid, any reference to dialysis fluid is for clarification and is not a requirement of the manufacturer.

This International Standard includes concentrates in both liquid and powder forms. Also included are additives, also called spikes, which are chemicals that may be added to the concentrate to increase the concentration of one or more of the existing ions in the concentrate and thus in the final dialysis fluid. This International Standard also gives requirements for equipment used to mix acid and bicarbonate powders into concentrate at the user's facility.

Concentrates prepared from prepackaged salts and water at a dialysis facility for use in that facility are excluded from the scope of this International Standard. Although references to dialysis fluid appear herein, this International Standard does not address dialysis fluid as made by the end user. Also excluded from the scope of this International Standard are requirements for the monitoring frequency of water purity used for the making of dialysis fluid by the dialysis facility. Recommendations from the technical committee responsible for this International Standard for monitoring water quality are contained in ISO 23500. This International Standard does not address bags of sterile dialysis fluid or sorbent dialysis fluid regeneration systems that regenerate and recirculate small volumes of the dialysis fluid.
ANSI : ANSI Approved
ISBN(s) : 1570205485
Number of Pages : 37
Published : 08/15/2014

History

AAMI 13958:2014
Published Date: 08/15/2014
Concentrates for hemodialysis and related therapies
AAMI RD61:2006
Published Date: 05/04/2007
Concentrates for hemodialysis
26.40 €
AAMI RD61
Published Date: 06/07/2001
Concentrates for hemodialysis
26.40 €

Related products

AAMI ST65:2008/(R)2018
Published Date: 03/04/2009
Processing of reusable surgical textiles for use in health care facilities
82.50 €
AAMI TIR29:2012/(R)2017
Published Date: 12/31/2012
Guide for process characterization and control in radiation sterilization of medical devices
77.70 €

Best-Selling Products

MEDDEV 13/93
Published Date:
Guidelines Relating to the Application of: The Council Directive 90/385/EEC on Active Implantable Medical Devices and The Council Directive 93/42/EEC on Medical Devices
MEDDEV 2.1/3
Published Date: 03/01/1998
Guidelines Relating to the Demarcation Between 90/385/EEC on Active Implatable Medical Devices, 93/42/EEC on Medical Devices,65/65/EEC Relating to Medicinal Products & Related Directives
MEDDEV 3/94
Published Date: 04/01/1994
Guidelines Relating to the Application of : The Council Directive 90/385/EEC on Active Implantable Medical Devices and The Council Directive 93/42/EEC on Medical Devices