AASHTO M 259M-11(2015) PDF

AASHTO M 259M-11(2015) PDF

Name:
AASHTO M 259M-11(2015) PDF

Published Date:
2011

Status:
Active

Description:

Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers [Metric] (ASTM Designation C 789M-98)

Publisher:
American Association of State Highway and Transportation Officials

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.1
Need Help?
This specification covers single-cell precast reinforced concrete box sections intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage.

This specification is the metric counterpart of M 259.

This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in the Appendices. The successful performance of this product depends upon the proper selection of the box section, bedding, and backfill, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading conditions and field requirements must properly correlate with the box section specified and that inspection at the construction site must be provided.

AASHTO M 273M is to be used for box sections with less than 0.6 m of cover subjected to highway loading.

If load-and-resistance factor design (LRFD) is required, then use ASTM C 1577.
File Size : 1 file , 1.8 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 29
Published : 2011

History

AASHTO M 259M-17
Published Date: 2017
Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers [Metric] (ASTM Designation C 789M-98)
$29.1
AASHTO M 259M-11(2015)
Published Date: 2011
Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers [Metric] (ASTM Designation C 789M-98)
$20.1

Related products

AASHTO M 259-23
Published Date: 2023
Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers Designed According to the AASHTO LRFD Bridge Design Specifications (ASTM Designation: C1577-20)
$33.3
AASHTO M 273M-17
Published Date: 2017
Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 0.6 m of Cover Subjected to Highway Loadings [Metric]
$26.7

Best-Selling Products

Internal Flow Systems
Published Date: 03/01/1990
$58.674