AASHTO R 32-19 PDF

AASHTO R 32-19 PDF

Name:
AASHTO R 32-19 PDF

Published Date:
2019

Status:
Active

Description:

Standard Recommended Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer

Publisher:
American Association of State Highway and Transportation Officials

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$26.7
Need Help?
AASHTO R 32-19 covers the annual calibration of the load cell and the deflection sensors and monthly relative calibration of the deflection sensors of a falling weight deflectometer (FWD) or a heavy weight deflectometer (HWD). It is used to establish calibration factors for correcting FWD and HWD measurements.

This procedure is not applicable to the calibration of light weight deflectometers or of cyclic loading and other types of pavement deflection testing equipment.

A reference calibration is performed once per year or after the load cell has been replaced on the FWD. It shall be performed by a certified technician.

Monthly relative calibration is performed on the deflection sensors at least once per month and immediately after a deflection sensor is replaced. A certified technician is not required.

The procedure results in calibration factors are entered into the FWD software as multipliers. When the FWD measurements are multiplied by the calibration factors the result is a set of measurements that have been corrected to agree with the calibration instrumentation.

Calibration procedures may vary slightly among FWD types. This procedure can be used for all types of FWDs with minor modifications within the limits of the reference calibration equipment.

This procedure has been automated in the software package WinFWDCal. It is required that the computer program be used to carry out the procedure.

To use this procedure, the FWD computer must be capable of electronic data transfer.

Data files for all types of FWDs can be read by the WinFWDCal software. The PDDX file format is required for data input. FWD data files that are in native format can be converted to PDDX format using PDDXconvert, which is an integral component in WinFWDCal.
File Size : 1 file , 1.3 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 14
Published : 2019

History

AASHTO R 32-20
Published Date: 2020
Standard Recommended Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer
$26.7
AASHTO R 32-19
Published Date: 2019
Standard Recommended Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer
$26.7
AASHTO R 32-11 (2015)
Published Date: 2011
Standard Recommended Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer
$26.7
AASHTO R 32-09
Published Date: 2009
Standard Recommended Practice for Calibrating the Load Cell and Deflection Sensors for a Falling Weight Deflectometer
$12

Related products

AASHTO T 316-22
Published Date: 2022
Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
$25.8
AASHTO T 30-21
Published Date: 2021
Standard Method of Test for Mechanical Analysis of Extracted Aggregate
$28.8
AASHTO T 129-23
Published Date: 2023
Standard Method of Test for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (ASTM Designation: C187-16)
$24.3

Best-Selling Products

Design for Earthquakes
Published Date: 01/01/1997
I C B O 9033C92
Published Date: 01/01/1992
CABO/ANSI A117.1 Commentary
ICBO 108H01
Published Date:
Principles of Fire Behavior
ICBO 108H02
Published Date:
Design of Water-Based Fire Protection Systems
ICBO 108H03
Published Date:
Hazardous Materials