API TR 756-1 PDF

API TR 756-1 PDF

Name:
API TR 756-1 PDF

Published Date:
09/01/2014

Status:
Active

Description:

Process Plant Tent Responses to Vapor Cloud Explosions - Results of the American Petroleum Institute Tent Testing Program, First Edition

Publisher:
American Petroleum Institute

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$63.6
Need Help?
Beginning in 2011, the American Petroleum Institute (API) to performed vapor cloud explosion (VCE) tests to determine the response of tents to the potential explosion hazards that may be present at refineries, petrochemical and chemical operations, natural gas and other onshore process facilities covered by OSHA 29 CFR 1910.119. The testing was conducted to provide data for use by the API committee developing API Recommended Practice (RP) 756, "Management of Hazards Associated with Location of Process Plant Tents". This publication, TR 756-1, contains information on the results of the API tent testing program.

For this program, a Deflagration Load Generator (DLG) test rig was used for these tests. The test rig measured 48 ft. long by 24 ft. deep by 12 ft. tall and had three rigid walls, a rigid roof and floor, and one open wall facing the structure being tested. The test rig is filled with a propane/air mixture and ignited, causing a VCE.

The tests were originally designed to serve multiple purposes:
  • Provide data on response of tents to a variety of blast loads ranging from 0.6 to 1.5 psi,
  • Identify the failure modes for different types of tents, and
  • Obtain data on tent response to support estimates on the vulnerability of tent occupants.
During the project the specific test environment was controlled through selection of fuel concentration, obstacle geometry, and the distance between the test article and the VCE test rig. The tests were deflagrations with moderate flame speeds such that the wave shape of the blast load would include a rise time to the peak pressure. This type of VCE is representative of typical accidental VCEs at industrial facilities.

In addition, the VCE deflagrations were set to vent outside the test rig, toward the test articles and the tents were placed at a sufficient range from the test rig such that three test articles could be tested simultaneously on each shot. The test rig was also configured such that the blast loading on the tent could be changed by varying the fuel concentration rather than relocating the test articles.
Edition : 1st
File Size : 1 file , 55 MB
Note : This product is unavailable in Ukraine, Russia, Cuba, Syria, Belarus, Iran, North Korea
Number of Pages : 597
Product Code(s) : C756101, C756101, C756101
Published : 09/01/2014

History


Related products

API RP 756
Published Date: 01/01/2024
Management of Hazards Associated with Location of Process Plant Tents, Second Edition
$46.2
API Publ 337
Published Date: 08/01/1996
Development of Emission Factors for Leaks in Refinery Components in Heavy Liquid Service
$43.2
API RP 751
Published Date: 08/01/2021
Safe Operation of Hydrofluoric Acid Alkylation Units, Fifth Edition
$60
API TR 755-1
Published Date: 04/01/2010
Fatigue Risk Management Systems for Personnel in the Refining and Petrochemical Industries, First Edition
$34.5

Best-Selling Products

AGA A25023
Published Date: 01/01/2005
2005 Handbook of Publicly Traded AGA Member Companies
$57
AGA A25024
Published Date: 01/01/2006
2006 Handbook of Publicly Traded AGA Member Companies
$57
AGA ANSI Z223.1-2024 / NFPA 54
Published Date: 2024
National Fuel Gas Code, 2024 Edition
$28.2
AGA ANSI Z223.1 Set
Published Date: 01/01/2002
National Fuel Gas Code and Handbook Set, 2002 Edition
AGA ANSI Z223.1 Set
Published Date: 01/01/2006
National Fuel Gas Code and Handbook Set, 2006 Edition
AGA ANSI Z223.1 Set
Published Date: 2009
National Fuel Gas Code and Handbook Set, 2009 Edition
$49.5