ASHRAE 1478: Measuring Airtightness of Mid- and High-Rise Non-Residential Buildings PDF

ASHRAE 1478: Measuring Airtightness of Mid- and High-Rise Non-Residential Buildings PDF

Name:
ASHRAE 1478: Measuring Airtightness of Mid- and High-Rise Non-Residential Buildings PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

ASHRAE 1478 is a research project designed to measure enclosure airtightness of mid- and high-rise buildings in the UnitedStates. Data were collected from 16 non-residential buildings in climate zones 2–7 constructed since the year 2000. The datasetincludes buildings with no particular attention to making the building airtight, buildings where some attention was given toairtightness, and buildings where extensive attention was paid to airtightness. Some of the buildings were designed to be sustainable(e.g., receiving LEED status). Buildings ranged from four to fourteen stories. A fan pressure testing protocol based on ASTME779 was developed by the project team. A number of issues in using E779 to test large building were identified, discussed, andaddressed. Building airtightness was reported inCFMper square foot of above grade enclosure at a 75 pascal induced shell pressuredifference and CFM per square foot of complete enclosure (including slab and below grade conditioned space walls). Theresults range from 0.06 cfm 75/ft2 to 0.75 cfm 75/ft2 of complete enclosure (1.10 m3/h/m2 to 13.7 m3/h/m2). Major air leakagesites were identified in the course of testing. Air leakage throughHVACrelated penetrations was measured in a subset of the buildings.Factors that are associated with the most airtight enclosures include air-barrier continuity detailed in construction documentsand precast concrete panel construction. Damper air leakage turned out to be a significant portion of the total enclosureair leakage in some of the buildings. The significance of air leakage by HVAC systems is reviewed in relation to building air tightness.

Presented at Thermal Performance of Exterior Envelopes of Whole Buildings XII, December 2013


File Size : 1 file , 410 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 6
Product Code(s) : D-BldConf13-54
Published : 2013

History


Related products


Best-Selling Products

DIN/VDI 3673
Published Date: 01/01/1979
Pressure Venting of Dust Explosions
$36