Standard 62.2-2007 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$14.1
Need Help?

(Supersedes ANSI/ASHRAE Standard 62.2-2004)
Includes ANSI/ASHRAE addenda listed in Appendix C

1. PURPOSE
This standard defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality (IAQ) in low-rise residential buildings.

2. SCOPE
This standard applies to spaces intended for human occupancy within single-family houses and multifamily structures of three stories or fewer above grade, including manufactured and modular houses. This standard does not apply to transient housing such as hotels, motels, nursing homes, dormitories, or jails.

2.1 This standard considers chemical, physical, and biological contaminants that can affect air quality. Thermal comfort requirements are not included in this standard (see ANSI/ ASHRAE Standard 55-2004, Thermal Environmental Conditions for Human Occupancy).

2.2 While acceptable indoor air quality is the goal of this standard, it will not necessarily be achieved even if all requirements are met
a. because of the diversity of sources and contaminants in indoor air and the range of susceptibility in the population;
b. because of the many other factors that may affect occupant perception and acceptance of IAQ, such as air temperature, humidity, noise, lighting, and psychological stress;
c. if the ambient air is unacceptable and this air is brought into the building without first being cleaned (cleaning of ambient outdoor air is not required by this standard);
d. if the systems are not operated and maintained as designed; or
e. when high-polluting events occur.

2.3 This standard does not address unvented combustion space heaters.

Preview this standard!


File Size : 1 file , 3.8 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 20
Product Code(s) : D-86158, 86158
Published : 2007

History

ASHRAE 62.2-2022
Published Date: 2022
Standard 62.2-2022 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings (ANSI Approved)
$42
ASHRAE 62.2-2019
Published Date: 2019
Standard 62.2-2019 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings- (ANSI Approved)
$31.5
ASHRAE 62.2-2013
Published Date: 2013
Standard 62.2-2013 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)
$20.4
ASHRAE 62.2-2010
Published Date: 2010
Standard 62.2-2010 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)
$19.5
ASHRAE 62.2-2007
Published Date: 2007
Standard 62.2-2007 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)
$14.1
ASHRAE 62.2-2004
Published Date: 2004
Standard 62.2-2004 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI Approved)
$13.2
ASHRAE 62.2-2003
Published Date: 2003
Standard 62.2-2003 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings
$13.2

Related products

ASHRAE 63.2-2024
Published Date: 2024
Standard 63.2-2024 -- Method of Testing Liquid-Line Filter Drier Filtration Capability (ANSI Approved)
$22.5

Best-Selling Products