Description:

Performance Requirements for Reduced Pressure Detector Backflow Prevention Assemblies

Publisher:
American Society of Sanitary Engineering

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$13.5
Need Help?

The purpose of a Reduced Pressure Detector Backflow Prevention Assembly is to keep contaminated water from flowing back into a potable water distribution system when some abnormality in the system causes the pressure to be temporarily higher in the contaminated part of the system than in the potable water supply piping. These assemblies are designed to detect low rates of flow up to 2.0 gpm (0.13 L/s) caused by leakage or unauthorized use.

 

This standard applies to the two types of assemblies identified as:

a) Reduced Pressure Detector Assembly (RPDA).

b) Reduced Pressure Detector Assembly Type II (RPDA-II).

 

The RPDA and RPDA-II assemblies consist of 2 independently acting check valves, internally force loaded to a normally closed position, and separated by an intermediate chamber (or zone) in which there is a hydraulically operated relief means for venting to the atmosphere, internally force loaded to a normally open position. These assemblies are designed to operate under continuous pressure conditions. The assembly shall include 2 properly located, tightly closing shut-off valves per Section 1.3.2.7; and properly located test cocks per Section 1.3.2.5. The assemblies also include a bypass line.


ANSI : ANSI Approved
File Size : 1 file , 1.3 MB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 36
Published : 06/01/2021

History

ASSE (Plumbing) 1047-2021
Published Date: 06/01/2021
Performance Requirements for Reduced Pressure Detector Backflow Prevention Assemblies
$13.5
ASSE (Plumbing) 1047-2011
Published Date: 08/17/2011
Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies
$13.5
ASSE (Plumbing) 1047-2005
Published Date: 01/01/2005
Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies

Related products

ASSE (Plumbing) 1053-2019 (R2023)
Published Date: 2019
Performance Requirements for Dual Check Backflow Preventer Wall Hydrants - Freeze Resistant Type
$13.5
ASSE (Plumbing) 1057-2023
Published Date: 2023
Performance Requirements for Freeze Resistant Sanitary Yard Hydrants with Backflow Protection
$13.5
ASSE (Plumbing) 1013-2021
Published Date:
Performance Requirements for Reduced Pressure Principle Backflow Prevention Assemblies
$13.5

Best-Selling Products

CDM Regulations Procedual Manual
Published Date: 01/01/1999
$25.5
Dynamics of Marine Ecosystems
Published Date: 09/01/1996
$21.6
Workmanship Standards Manual
Published Date: 09/01/1997
$28.5