AAMI/ISO 26722:2009 PDF

AAMI/ISO 26722:2009 PDF

Name:
AAMI/ISO 26722:2009 PDF

Published Date:
04/22/2011

Status:
Active

Description:

Water treatment equipment for hemodialysis applications and related therapies

Publisher:
Association for the Advancement of Medical Instrumentation/International Org. for Standardization

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$42.9
Need Help?
This International Standard is addressed to the manufacturer and/or supplier of water treatment systems and/or devices used for the express purpose of providing water for hemodialysis or related therapies.

This International Standard covers devices used to treat water intended for use in the delivery of hemodialysis and related therapies. Included in the scope of this International Standard is water used for:
(1) the preparation of concentrates from powder or other highly concentrated media at a dialysis facility;
(2) the preparation of dialysis fluid that may be used for the preparation of substitution fluid; (3) the reprocessing of dialyzers for multiple uses.

Included within the scope of this International Standard are all devices, piping and fittings between the point at which potable water is delivered to the water treatment system and the point of use of the dialysis water. Examples of devices included within the scope of this International Standard are water purification devices, online water quality monitors (such as conductivity monitors), and piping systems for the distribution of dialysis water.

Excluded from the scope of this International Standard are dialysis fluid supply systems that proportion water and concentrates to produce dialysis fluid, sorbent dialysis fluid regeneration systems that regenerate and recirculate small volumes of the dialysis fluid, dialysis concentrates, hemodiafiltration systems, hemofiltration systems, systems that process dialyzers for multiple uses, and peritoneal dialysis systems. Some of these devices, such as dialysis fluid delivery systems and concentrates, are addressed in other International Standards. Also excluded from the scope of this International Standard are requirements for the ongoing monitoring of the purity of water used for dialysis fluid, concentrate preparation or dialyzer reprocessing.
ANSI : ANSI Approved
File Size : 1 file , 440 KB
ISBN(s) : 1570204144
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 45
Published : 04/22/2011
Same As : AAMI/ISO 26722:2009

History

AAMI/ISO 23500-2:2019
Published Date: 12/23/2019
Preparation and quality management of fluids for haemodialysis and related therapies - Part 2: Water treatment equipment for haemodialysis applications and related therapies
$77.7
AAMI/ISO 26722:2009
Published Date: 04/22/2011
Water treatment equipment for hemodialysis applications and related therapies
$42.9

Related products

AAMI/ISO 15223-1:2022
Published Date: 01/09/2023
Medical devices - Symbols to be used with medical device labels, labeling, and information to be supplied - Part 1: General requirements
$82.2
AAMI/ISO 17665-1:2006/(R)2013
Published Date: 12/09/2005
Sterilization of health care products - Moist heat - Part 1 Requirements for the development, validation and routine control of a sterilization process for medical devices
$77.7
AAMI/ISO TIR19218-2:2012
Published Date: 12/10/2012
Medical devices -Hierarchical coding structure for adverse events - Part 2: Evaluation codes
$40.5
AAMI/ISO TIR16775:2023
Published Date: 08/18/2023
Packaging for terminally sterilized medical devices—Guidance on the application of ISO 11607-1 and ISO 11607-2
$122.1

Best-Selling Products