Standard Practice for Use of an Alanine-EPR Dosimetry System

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18.9
Need Help?
1.1 This practice covers dosimeter materials, instrumentation, and procedures for using the alanine-EPR dosimetry system to measure the absorbed dose in the photon or electron radiation processing of materials. The alanine system is based on electron paramagnetic resonance (EPR) spectroscopy of free radicals derived from the amino acid alanine.2
1.2 The alanine dosimeter is classified as a type I dosimeter as it is affected by individual influence quantities in a well-defined way that can be expressed in terms of independent correction factors (see ISO/ASTM Practice 52628). The alanine dosimeter may be used in either a reference standard dosimetry system or in a routine dosimetry system.
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 "Practice for Dosimetry in Radiation Processing" for alanine dosimetry system. It should be read in conjunction with ISO/ASTM 52628.
1.4 This practice covers the use of alanine-EPR dosimetry systems under the following conditions:
1.4.1 The absorbed dose range is between 0.001 kGy and 150 kGy.
1.4.2 The absorbed dose rate is up to 1 × 10² Gy s-1 for continuous radiation fields and up to 3 × 1010 Gy s-1 for pulsed radiation fields (1-4).3
1.4.3 The radiation energy for photons and electrons is between 0.1 MeV and 30 MeV (1, 2, 5-8).
1.4.4 The irradiation temperature is between -78 °C and +70 °C (2, 9-12).
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

File Size : 1 file , 310 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 7
Published : 01/01/2022
Redline File Size : 2 files , 420 KB

History

ASTM 51607-22
Published Date: 01/01/2022
Standard Practice for Use of an Alanine-EPR Dosimetry System
$18.9
ASTM E1607-96e1
Published Date: 05/01/1996
Standard Practice for Use of the Alanine-EPR Dosimetry System (Withdrawn 2002)
$17.4

Related products

ASTM E722-19
Published Date: 10/01/2019
Standard Practice for Characterizing Neutron Fluence Spectra in Terms of an Equivalent Monoenergetic Neutron Fluence for Radiation-Hardness Testing of Electronics
$21.6
ASTM E1175-87(2022)
Published Date: 10/01/2022
Standard Test Method for Determining Solar or Photopic Reflectance, Transmittance, and Absorptance of Materials Using a Large Diameter Integrating Sphere
$15
ASTM E2450-23
Published Date: 01/01/2023
Standard Practice for Application of CaF2(Mn) Thermoluminescence Dosimeters in Mixed Neutron-Photon Environments
$17.1
ASTM E170-24
Published Date: 05/01/2024
Standard Terminology Relating to Radiation Measurements and Dosimetry
$20.7

Best-Selling Products