Description:

Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.1
Need Help?

1.1 These practices cover the following five tests:

1.1.1 Practice A - Oxalic Acid Etch Test for Classification of Etch Structures of Austenitic Stainless Steels (Sections 3 to 7, inclusive),

1.1.2 Practice B - Ferric Sulfate-Sulfuric Acid Test for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels (Sections 8 to 14, inclusive),

1.1.3 Practice C - Nitric Acid Test for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels (Sections 15 to 21, inclusive),

1.1.4 Practice E - Copper-Copper Sulfate-Sulfuric Acid Test for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels (Sections 22 to 31, inclusive), and

1.1.5 Practice F - Copper-Copper Sulfate-50% Sulfuric Acid Test for Detecting Susceptibility to Intergranular Attack in Molybdenum-Bearing Cast Austenitic Stainless Steels (Sections 32 to 38, inclusive).

1.2 The following factors govern the application of these practices:

1.2.1 Susceptibility to intergranular attack associated with the precipitation of chromium carbides is readily detected in all six tests.

1.2.2 Sigma phase in wrought chromium-nickel-molybdenum steels, which may or may not be visible in the microstructure, can result in high corrosion rates only in nitric acid.

1.2.3 Sigma phase in titanium or columbium stabilized alloys and cast molybdenum bearing stainless alloys, which may or may not be visible in the microstructure, can result in high corrosion rates in both the nitric acid and ferric sulfate-sulfuric acid solutions.

1.3 The oxalic acid etch test is a rapid method of identifying, by simple etching, those specimens of certain stainless steel grades which are essentially free of susceptibility to intergranular attack associated with chromium carbide precipitates. These specimens will have low corrosion rates in certain corrosion tests and therefore can be eliminated (screened) from testing as "acceptable."

1.4 The ferric sulfate-sulfuric acid test, the copper-copper sulfate-50% sulfuric acid test, and the nitric acid test are based on weight loss determinations and, thus, provide a quantitative measure of the relative performance of specimens evaluated. In contrast, the copper-copper sulfate-16% sulfuric acid test is based on visual examination of bend specimens and, therefore, classifies the specimens only as acceptable or non-acceptable.

1.5 In most cases either the 24-h copper-copper sulfate-16% sulfuric acid test or the 120-h ferric sulfate-sulfuric acid test, combined with the oxalic acid etch test, will provide the required information in the shortest time. All stainless grades listed in the accompanying table may be evaluated in these combinations of screening and corrosion tests, except those specimens of molybdenum-bearing grades (for example 316, 316L, 317, and 317L), which represent steel intended for use in nitric acid environments.

1.6 The 240-h nitric acid test must be applied to stabilized and molybdenum-bearing grades intended for service in nitric acid and to all stainless steel grades which might be subject to end grain corrosion in nitric acid service.

1.7 Only those stainless steel grades are listed in Table 1 for which data on the application of the oxalic acid etch test and on their performance in various quantitative evaluation tests are available.

1.8 Extensive test results on various types of stainless steels evaluated by these practices have been published in Ref (1).

1.9 The values stated in SI units are to be regarded as standard. The inch-pound equivalents are in parentheses and may be approximate.

1.10 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Specific precautionary statements are given in 5.6, 11.1.1, 11.1.9, and 35.1.)


File Size : 1 file , 930 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 17
Published : 11/10/2002

History

ASTM A262-15(2021)
Published Date: 09/01/2021
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$18
ASTM A262-14
Published Date: 07/01/2014
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.7
ASTM A262-13
Published Date: 05/01/2013
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-10
Published Date: 04/01/2010
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-02a(2008)
Published Date: 03/01/2008
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-02ae3
Published Date: 11/10/2002
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-02ae2
Published Date: 11/10/2002
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-02ae1
Published Date: 11/10/2002
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-02a
Published Date: 11/10/2002
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-02
Published Date: 06/10/2002
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.1
ASTM A262-98
Published Date: 09/10/2001
Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
$20.7

Related products

ASTM A905-19
Published Date: 09/01/2019
Standard Specification for Steel Wire, Pressure Vessel Winding
$13.2
ASTM A794/A794M-24
Published Date: 05/01/2024
Standard Specification for Commercial Steel (CS), Sheet, Carbon (0.16 % Maximum to 0.25 % Maximum), Cold-Rolled
$16.5
ASTM A1084-15a(2022)
Published Date: 06/01/2022
Standard Test Method for Detecting Detrimental Phases in Lean Duplex Austenitic/Ferritic Stainless Steels
$18
ASTM A805/A805M-09(2021)
Published Date: 09/01/2021
Standard Specification for Steel, Flat Wire, Carbon, Cold-Rolled
$18

Best-Selling Products

CAN/ULC 554-05 (R2010)
Published Date: 10/04/2011
Standard for Water Based Agent Fire Extinguishers, Including Amendment 1
CAN/ULC 60832-09
Published Date: 04/09/2009
Insulating poles (Insulating Sticks) and Universal Tool Attachments (Fitting) for Live Working
CAN/ULC 60895-09 Draft
Published Date: 01/01/2009
Live Working - Conductive Clothing For Use at Nominal Voltage Up to 800 kV A.C. and ?600 kV D.C.
CAN/ULC 60903-09
Published Date:
Live Working - Gloves of Insulating Material
CAN/ULC 61243-3-10
Published Date: 12/01/2010
Live working -- Voltage Detectors -- Part 3: Two-Pole Low-Voltage Type
CAN/ULC 61477-05
Published Date: 01/01/2006
Live Working - Minimum Requirements for the Utilization of Tools, Devices and Equipment (CEI/IEC 61477:2001+A1:2002, IDT)