ASTM A804/A804M-04 PDF

ASTM A804/A804M-04 PDF

Name:
ASTM A804/A804M-04 PDF

Published Date:
05/01/2004

Status:
Active

Description:

Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.1
Need Help?

1.1 These test methods cover the determination of specific core loss and peak permeability of single layers of sheet-type specimens tested with normal excitation at a frequency of 50 or 60 Hz.

Note 1 - These test methods have been applied only at the commercial power frequencies, 50 and 60 Hz, but with proper instrumentation and application of the principles of testing and calibration embodied in the test methods, they are believed to be adaptable to testing at frequencies ranging from 25 to 400 Hz.

1.2 These test methods use calibration procedures that provide correlation with the 25-cm [250-mm] Epstein test.

1.3 The range of test magnetic flux densities is governed by the properties of the test specimen and by the available instruments and other equipment components. Normally, nonoriented electrical steels can be tested over a range from 8 to 16 kG [0.8 to 1.6 T] for core loss. For oriented electrical steels, the normal range extends to 18 kG [1.8 T]. Maximum magnetic flux densities in peak permeability testing are limited principally by heating of the magnetizing winding and tests are limited normally to a maximum ac magnetic field strength of about 150 Oe [12 000 A/m].

1.4 These test methods cover two alternative procedures as follows:

Test Method 1 - Sections 6-12

Test Method 2 - Sections 13-19

1.4.1 Test Method 1 uses a test fixture having (1) two windings that encircle the test specimen, and (2) a ferromagnetic yoke structure that serves as the flux return path and has low core loss and low magnetic reluctance.

1.4.2 Test Method 2 uses a test fixture having (1) two windings that encircle the test specimen, (2) a third winding located inside the other two windings and immediately adjacent to one surface of the test specimen, and (3) a ferromagnetic yoke structure which serves as the flux-return path and has low magnetic reluctance.

1.5 The values and equations stated in customary (cgs-emu and inch-pound) units or SI units are to be regarded separately as standard. Within this standard, SI units are shown in brackets except for the sections concerning calculations where there are separate sections for the respective unit systems. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 170 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 16
Published : 05/01/2004
Redline File Size : 2 files , 320 KB

History

ASTM A804/A804M-04(2021)
Published Date: 02/01/2021
Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens
$17.4
ASTM A804/A804M-04(2009)e1
Published Date: 05/01/2009
Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens
$20.1
ASTM A804/A804M-04
Published Date: 05/01/2004
Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens
$20.1
ASTM A804/A804M-99
Published Date: 05/10/1999
Standard Test Methods for Alternating-Current Magnetic Properties of Materials at Power Frequencies Using Sheet-Type Test Specimens
$19.5

Related products

ASTM A927/A927M-18(2022)
Published Date: 10/01/2022
Standard Test Method for Alternating-Current Magnetic Properties of Toroidal Core Specimens Using the Voltmeter-Ammeter-Wattmeter Method
$17.1
ASTM E2479-16(2021)
Published Date: 06/01/2021
Standard Practice for Measuring the Ultrasonic Velocity in Polyethylene Tank Walls Using Lateral Longitudinal (LCR) Waves
$15.6
ASTM A893/A893M-03(2022)
Published Date: 10/01/2022
Standard Test Method for Complex Dielectric Constant of Nonmetallic Magnetic Materials at Microwave Frequencies
$15
ASTM E2662-15(2022)
Published Date: 12/01/2022
Standard Practice for Radiographic Examination of Flat Panel Composites and Sandwich Core Materials Used in Aerospace Applications
$17.1

Best-Selling Products

INCITS 100-1989(R1995) Add. 1:1991
Published Date: 01/01/1991
Addendum 1 to ANSI/NCITS X3.100-1989, Interface Between DTE & DCE for Packet Mode Operation with Packet Switch Data Communications Networks - NUI and NUI-Derived Facility Extensions (formerly ANSI X3.100-1989(R1995) Add.1:1991)
INCITS 100-1989(R1995)
Published Date: 01/01/1989
Interface Between DTE & DCE for Packet Mode Operation with Packet Switch Data Communications Networks (CCITT X.25) (formerly ANSI X3.100-1989(R1995)
INCITS 103-1983(R1996)
Published Date: 01/01/1983
Unrecorded Magnetic Tape Minicassette For Information Interchange, Coplanar 3.81 mm (0.150 Inch) (formerly ANSI X3.103-1983(R1996))
INCITS 11-1990(R2002)
Published Date: 01/01/1990
Specification for General Purpose Paper Cards for Information Interchange (formerly ANSI X3.11-1990(R2002))
$18
INCITS 111-1986(R1997)
Published Date: 01/01/1986
Matrix Character Sets for Optical Character Recognition (OCR-M) (formerly ANSI X3.111-1986(R1997))
INCITS 112-1984(R1996)
Published Date: 01/01/1984
14-Inch (356 mm) Diameter Low Surface Friction Magnetic Storage Disk (formerly ANSI X3.112-1984(R1996))