ASTM B812-96(2008) PDF

ASTM B812-96(2008) PDF

Name:
ASTM B812-96(2008) PDF

Published Date:
03/01/2008

Status:
Active

Description:

Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-b812-96-2008_1557442

Choose Document Language:
20.10 €
Need Help?

1.1 This test method covers all residential pressure connection systems. Detailed examples of application to specific types of connection systems, set-screw neutral bus connectors and twist-on wire-splicing connectors, are provided in Appendix X1 and Appendix X2.

1.2 The purpose of this test method is to evaluate the performance of residential electrical pressure connection systems under conditions of cyclic temperature change (within rating) and high humidity.

1.3 The limitations of the test method are as follows:

1.3.1 This test method shall not be considered to confirm a specific lifetime in application environments.

1.3.2 The applicability of this test method is limited to pressure connection systems rated at or below 600 V d-c or a-c RMS.

1.3.3 This test method is limited to temperature and water vapor exposure in addition to electrical current as required to measure connection resistance.

1.3.4 This test method does not evaluate degradation which may occur in residential applications due to exposure of the electrical connection system to additional environmental constituents such as (but not limited to) the following examples:

1.3.4.1 Household chemicals (liquid or gaseous) such as ammonia, bleach, or other cleaning agents.

1.3.4.2 Chemicals as may occur due to normal hobby or professional activities such as photography, painting, sculpture, or similar activities.

1.3.4.3 Environments encountered during construction or remodeling such as direct exposure to rain, uncured wet concrete, welding or soldering fluxes and other agents.

1.3.5 This test method is limited to evaluation of pressure connection systems.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to become familiar with all hazards including those identified in the appropriate Material Safety Data Sheet (MSDS) for this product/material as provided by the manufacturer, to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.

1.5 This standard should be used to measure and describe the properties of materials, products, or assemblies in response to electrical current flow under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual installation conditions or under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use.


File Size : 1 file , 180 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 11
Published : 03/01/2008

History

ASTM B812-18(2024)
Published Date: 04/01/2024
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
20.70 €
ASTM B812-18
Published Date: 11/01/2018
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
24.90 €
ASTM B812-96(2013)
Published Date: 08/01/2013
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
20.10 €
ASTM B812-96(2008)
Published Date: 03/01/2008
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
20.10 €
ASTM B812-96(2002)e1
Published Date: 05/10/1996
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
20.10 €
ASTM B812-96
Published Date: 05/10/1996
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
20.70 €

Related products

ASTM B561-23
Published Date: 04/01/2023
Standard Specification for Refined  Platinum
15.00 €
ASTM B777-15(2020)
Published Date: 04/01/2020
Standard Specification for Tungsten Base, High-Density Metal
13.20 €
ASTM B725-22
Published Date: 04/01/2022
Standard Specification for Welded Nickel and Nickel Copper Alloy Pipe
17.10 €

Best-Selling Products

NCSL CALIB
Published Date:
Calibration Laboratory Manager´s Guidebook
NCSL RISP-1
Published Date: 01/01/2017
Josephson Voltage Standard
NCSL RISP-3
Published Date: 08/01/1997
Quantized Hall Resistance
NCSL RISP-4
Published Date: 07/01/1998
Deadweight Pressure Gauges
NCSL RISP-5
Published Date: 01/01/2017
Two-Pressure, Two Temperature Humidity Generator
NCSL RP-10
Published Date: 01/01/2004
Operation of Electric Utility Metrology Lab