1.1 This test method covers all residential pressure connection systems. Detailed examples of application to specific types of connection systems, set-screw neutral bus connectors and twist-on wire-splicing connectors, are provided in Appendix X1 and Appendix X2.

1.2 The purpose of this test method is to evaluate the performance of residential electrical pressure connection systems under conditions of cyclic temperature change (within rating) and high humidity.

1.3 The limitations of the test method are as follows:

1.3.1 This test method shall not be considered to confirm a specific lifetime in application environments.

1.3.2 The applicability of this test method is limited to pressure connection systems rated at or below 600 V d-c or a-c RMS.

1.3.3 This test method is limited to temperature and water vapor exposure in addition to electrical current as required to measure connection resistance.

1.3.4 This test method does not evaluate degradation which may occur in residential applications due to exposure of the electrical connection system to additional environmental constituents such as (but not limited to) the following examples:

1.3.4.1 Household chemicals (liquid or gaseous) such as ammonia, bleach, or other cleaning agents.

1.3.4.2 Chemicals as may occur due to normal hobby or professional activities such as photography, painting, sculpture, or similar activities.

1.3.4.3 Environments encountered during construction or remodeling such as direct exposure to rain, uncured wet concrete, welding or soldering fluxes and other agents.

1.3.5 This test method is limited to evaluation of pressure connection systems.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to become familiar with all hazards including those identified in the appropriate Material Safety Data Sheet (MSDS) for this product/material as provided by the manufacturer, to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.

1.5 This standard should be used to measure and describe the properties of materials, products, or assemblies in response to electrical current flow under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual installation conditions or under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use.


File Size : 1 file , 180 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 11
Published : 03/01/2008

History

ASTM B812-18(2024)
Published Date: 04/01/2024
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
$20.7
ASTM B812-18
Published Date: 11/01/2018
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
$24.9
ASTM B812-96(2013)
Published Date: 08/01/2013
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
$20.1
ASTM B812-96(2008)
Published Date: 03/01/2008
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
$20.1
ASTM B812-96(2002)e1
Published Date: 05/10/1996
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
$20.1
ASTM B812-96
Published Date: 05/10/1996
Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications
$20.7

Related products

ASTM B561-23
Published Date: 04/01/2023
Standard Specification for Refined  Platinum
$15
ASTM B777-15(2020)
Published Date: 04/01/2020
Standard Specification for Tungsten Base, High-Density Metal
$13.2
ASTM B725-22
Published Date: 04/01/2022
Standard Specification for Welded Nickel and Nickel Copper Alloy Pipe
$17.1

Best-Selling Products

ISO/HL7 10781:2015
Published Date: 08/01/2015
Health Informatics - HL7 Electronic Health Records-System Functional Model, Release 2 (EHR FM)
$71.1
ISO/HL7 16527:2016
Published Date: 08/01/2016
Health informatics - HL7 Personal Health Record System Functional Model, Release 1 (PHRS FM)
$71.1
ISO/HL7 21731:2014
Published Date: 08/01/2014
Health informatics - HL7 version 3 - Reference information model - Release 4
$66.9
ISO/HL7 27931:2009
Published Date: 08/01/2009
Data Exchange Standards - Health Level Seven Version 2.5 - An application protocol for electronic data exchange in healthcare environments
$83.4
ISO/HL7 27932:2009
Published Date: 08/01/2009
Data Exchange Standards - HL7 Clinical Document Architecture, Release 2
$83.4
ISO/HL7 27951:2009
Published Date: 08/01/2009
Health informatics - Common terminology services, release 1
$83.4