ASTM C1044-98(2003) PDF

ASTM C1044-98(2003) PDF

Name:
ASTM C1044-98(2003) PDF

Published Date:
04/10/2003

Status:
Active

Description:

Standard Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-c1044-98-2003_1094244

Choose Document Language:
18.00 €
Need Help?

1.1 This practice covers the determination of the steady-state heat flow through the meter section of a specimen when a guarded-hot-plate apparatus or thin-heater apparatus is used in the single-sided mode of operation.

1.2 This practice provides a supplemental procedure for use in conjunction with either Test Method C 177 or C 1114 for testing a single specimen. This practice is limited to only the single-sided mode of operation, and, in all other particulars, the requirements of either Test Method C 177 or C 1114 apply.

Note 1 - Test Methods C 177 and C 1114 describe the use of the guarded-hot-plate and thin-heater apparatus, respectively, for determining steady-state heat flux and thermal transmission properties of flat-slab specimens. In principle, these methods cover both the double- and single-sided mode of operation, and at present, do not distinguish between the accuracies for the two modes of operation. When appropriate, thermal transmission properties shall be calculated in accordance with Practice C 1045.

1.3 This practice requires that the cold plates of the apparatus have independent temperature controls. For the single-sided mode of operation, a (single) specimen is placed between the hot plate and the cold plate. Auxiliary thermal insulation, if needed, is placed between the hot plate and the auxiliary cold plate. The auxiliary cold plate and the hot plate are maintained at essentially the same temperature. Ideally, the heat flow from the meter plate is assumed to flow only through the specimen, so that the thermal transmission properties correspond only to the specimen.

Note 2 - The double-sided mode of operation requires similar specimens placed on either side of the hot plate. The cold plates that contact the outer surfaces of these specimens are maintained at essentially the same temperature. The electric power supplied to the meter plate is assumed to result in equal heat flow through the meter section of each specimen, so that the thermal transmission properties correspond to an average for the two specimens.

1.4 This practice does not preclude the use of a guarded-hot-plate apparatus in which the auxiliary cold plate may be either larger or smaller in lateral dimensions than either the test specimen or the cold plate.

Note 3 - Most guarded-hot-plate apparatus are designed for the double-sided mode of operation (). Consequently, the cold plate and the auxiliary cold plate are the same size and the specimen and the auxiliary insulation will have the same lateral dimensions, although the thickness may be different. Some guarded-hot-plate apparatus, however, are designed specifically for testing only a single specimen that may be either larger or smaller in lateral dimensions than that auxiliary insulation or the auxiliary cold plate.

1.5 This practice can be used for both low- and high-temperature conditions.

1.6 This practice shall not be used when operating an apparatus in a double-sided mode of operation with a known and unknown specimen, that is, with the two cold plates at similar temperatures so that the temperature differences across the known and unknown specimens are similar.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 120 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 8
Published : 04/10/2003

History

ASTM C1044-24
Published Date: 03/01/2024
Standard Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode
18.90 €
ASTM C1044-16(2020)
Published Date: 10/01/2020
Standard Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode
22.50 €
ASTM C1044-12
Published Date: 03/01/2012
Standard Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode
18.00 €
ASTM C1044-07
Published Date: 09/01/2007
Standard Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode
18.00 €
ASTM C1044-98(2003)
Published Date: 04/10/2003
Standard Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode
18.00 €
ASTM C1044-98
Published Date: 05/10/1998
Standard Practice for Using the Guarded-Hot-Plate Apparatus in the One-Sided Mode to Measure Steady-State Heat Flux and Thermal Transmission Properties
16.20 €

Related products

ASTM E1408-91(2000)
Published Date: 03/10/2000
Standard Test Method for Laboratory Measurement of the Sound Transmission Loss of Door Panels and Door Systems (Withdrawn 2009)
17.40 €
ASTM C930-19
Published Date: 01/01/2019
Standard Classification of Potential Health and Safety Concerns Associated With Thermal Insulation Materials and Accessories
14.40 €
ASTM C1043-24
Published Date: 03/01/2024
Standard Practice for Guarded-Hot-Plate Design Using Circular Line-Heat Sources
20.70 €

Best-Selling Products

ISO/R 1938-1:1971
Published Date: 01/01/1971
ISO system of limits and fits - Part 1: Inspection of plain workpieces
30.60 €
ISO/R 1938:1971
Published Date: 02/01/1971
ISO system of limits and fits - Part II : Inspection of plain workpieces
44.70 €
ISO/R 463:1965
Published Date: 12/01/1965
Dial gauges reading in 0.01 mm, 0.001 in and 0.0001 in
9.90 €
ISO/R 538:1967
Published Date: 01/01/1967
Conventional signs to be used in the schemes for the installations of pipeline systems in ships
36.90 €
ISO/R 644:1967
Published Date: 12/01/1967
Conventional signs to be used in schemes for the installations of ventilation systems in ships
36.90 €
ISO/R 773:1969
Published Date: 01/01/1969
Rectangular or Square Parallel Keys and their Corresponding Keyways (Dimensions in Millimetres)
19.50 €