ASTM C1285-14 PDF

ASTM C1285-14 PDF

Name:
ASTM C1285-14 PDF

Published Date:
01/01/2014

Status:
Active

Description:

Standard Test Methods for Determining Chemical Durability of Nuclear, Hazardous, and Mixed Waste Glasses and Multiphase Glass Ceramics: The Product Consistency Test (PCT)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$26.7
Need Help?

1.1 These product consistency test methods A and B provide a measure of the chemical durability of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, multiphase glass ceramic waste forms, or combinations thereof, hereafter collectively referred to as “glass waste forms” by measuring the concentrations of the chemical species released to a test solution under carefully controlled conditions.

1.1.1 Test Method A is a seven-day chemical durability test performed at 90 ± 2°C in a leachant of ASTM-Type I water. The test method is static and conducted in stainless steel vessels. The stainless steel vessels require a gasket to remain leak-tight.2 The stainless steel vessels are considered to be “closed system” tests. Test Method A can specifically be used to evaluate whether the chemical durability and elemental release characteristics of nuclear, hazardous, and mixed glass waste forms have been consistently controlled during production. This test method is applicable to radioactive and simulated glass waste forms as defined above.

1.1.2 Test Method B is a durability test that allows testing at various test durations, test temperatures, particle size and masses of glass sample, leachant volumes, and leachant compositions. This test method is static and can be conducted in stainless steel or PFA TFE-fluorocarbon vessels. The stainless steel vessels are considered to be “closed system” while the PFA TFE-fluorocarbon vessels are considered to be “open system” tests. Test Method B can specifically be used to evaluate the relative chemical durability characteristics of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, or multiphase glass ceramic waste forms, or combinations thereof. This test method is applicable to radioactive (nuclear) and mixed, hazardous, and simulated glass waste forms as defined above. Test Method B cannot be used as a consistency test for production of high level radioactive glass waste forms.

1.2 These test methods must be performed in accordance with all quality assurance requirements for acceptance of the data.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 680 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 27
Published : 01/01/2014
Redline File Size : 2 files , 1.8 MB

History

ASTM C1285-21
Published Date: 02/01/2021
Standard Test Methods for Determining Chemical Durability of Nuclear, Hazardous, and Mixed Waste Glasses and Multiphase Glass Ceramics: The Product Consistency Test (PCT)
$22.5
ASTM C1285-14
Published Date: 01/01/2014
Standard Test Methods for Determining Chemical Durability of Nuclear, Hazardous, and Mixed Waste Glasses and Multiphase Glass Ceramics: The Product Consistency Test (PCT)
$26.7
ASTM C1285-02(2008)
Published Date: 07/01/2008
Standard Test Methods for Determining Chemical Durability of Nuclear, Hazardous, and Mixed Waste Glasses and Multiphase Glass Ceramics: The Product Consistency Test (PCT)
$25.8
ASTM C1285-02
Published Date: 06/10/2002
Standard Test Methods for Determining Chemical Durability of Nuclear, Hazardous, and Mixed Waste Glasses and Multiphase Glass Ceramics: The Product Consistency Test (PCT)
$25.8
ASTM C1285-97
Published Date: 10/10/1997
Standard Test Methods for Determining Chemical Durability of Nuclear, Hazardous, and Mixed Waste Glasses: The Product Consistency Test (PCT)
$19.5

Related products

ASTM C1236-99(2005)
Published Date: 06/01/2005
Standard Guide for In-Plant Performance Evaluation of Automatic Vehicle SNM Monitors (Withdrawn 2014)
$15.6
ASTM C1345-08
Published Date: 01/01/2008
Standard Test Method for Analysis of Total and Isotopic Uranium and Total Thorium in Soils by Inductively Coupled Plasma-Mass Spectrometry (Withdrawn 2015)
$20.1
ASTM C1008-99(2008)
Published Date: 01/01/2008
Standard Specification for Sintered (Uranium-Plutonium) Dioxide Pellets-Fast Reactor Fuel (Withdrawn 2014)
$15.6
ASTM C1344-97(2013)
Published Date: 07/01/2013
Standard Test Method for Isotopic Analysis of Uranium Hexafluoride by Single-Standard Gas Source Mass Spectrometer Method (Withdrawn 2020)
$18

Best-Selling Products

ISO/IWA 1:2005
Published Date: 10/01/2005
Quality management systems - Guidelines for process improvements in health service organizations
$39.6
ISO/IWA 11:2012
Published Date: 2012
Guidelines for evaluating cookstove performance
$13.5
ISO/IWA 12:2013
Published Date: 12/15/2013
Guidelines on the application of ISO 9001:2008 in policing organizations
$55.5
ISO/IWA 13:2014
Published Date: 11/15/2014
Multiple resource evaluation guideline
$23.1
ISO/IWA 14-1:2013
Published Date: 11/15/2013
Vehicle security barriers - Part 1: Performance requirement, vehicle impact test method and performance rating
$63
ISO/IWA 14-2:2013
Published Date: 11/15/2013
Vehicle security barriers - Part 2: Application
$71.1