ASTM C1332-18 PDF

ASTM C1332-18 PDF

Name:
ASTM C1332-18 PDF

Published Date:
02/01/2018

Status:
Active

Description:

Standard Practice for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$24.9
Need Help?

1.1 This practice describes a procedure for measurement of ultrasonic attenuation coefficients for advanced structural ceramic materials. The procedure is based on a broadband buffered piezoelectric probe used in the pulse-echo contact mode and emitting either longitudinal or shear waves. The primary objective of this practice is materials characterization.

1.2 The procedure requires coupling an ultrasonic probe to the surface of a plate-like sample and the recovery of successive front surface and back surface echoes (refer to Fig. 3). Power spectra of the echoes are used to calculate the attenuation spectrum (attenuation coefficient as a function of ultrasonic frequency) for the sample material. The transducer bandwidth and spectral response are selected to cover a range of frequencies and corresponding wavelengths that interact with microstructural features of interest in solid test samples.

1.3 The purpose of this practice is to establish fundamental procedures for measurement of ultrasonic attenuation coefficients. These measurements should distinguish and quantify microstructural differences among solid samples and therefore help establish a reference database for comparing materials and calibrating ultrasonic attenuation measurement equipment.

1.4 This practice applies to monolithic ceramics and also polycrystalline metals. This practice may be applied to whisker reinforced ceramics, particulate toughened ceramics, and ceramic composites provided that similar constraints on sample size, shape, and finish are met as described herein for monolithic ceramics.

1.5 This practice sets forth the constraints on sample size, shape, and finish that will assure valid attenuation coefficient measurements. This practice also describes the instrumentation, methods, and data processing procedures for accomplishing the measurements.

1.6 This practice is not recommended for highly attenuating materials such as very thick, very porous, rough-surfaced monolithics or composites. This practice is not recommended for highly nonuniform, heterogeneous, cracked, defective, or otherwise flaw-ridden samples that are unrepresentative of the nature or inherent characteristics of the material under examination.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 300 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 12
Published : 02/01/2018
Redline File Size : 2 files , 660 KB

History

ASTM C1332-18(2023)
Published Date: 12/01/2023
Standard Practice for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique
$20.7
ASTM C1332-18
Published Date: 02/01/2018
Standard Practice for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique
$24.9
ASTM C1332-01(2013)
Published Date: 02/01/2013
Standard Test Method for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique
$20.1
ASTM C1332-01(2007)
Published Date: 08/01/2007
Standard Test Method for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique
$20.1
ASTM C1332-01
Published Date: 05/10/2001
Standard Test Method for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique
$18
ASTM C1332-96
Published Date: 01/01/1996
Standard Test Method for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique
$17.4

Related products

ASTM E2339-21
Published Date: 12/01/2021
Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)
$18
ASTM E2598/E2598M-13
Published Date: 01/01/2013
Standard Practice for Acoustic Emission Examination of Cast Iron Yankee and Steam Heated Paper Dryers
$14.4
ASTM E1165-20
Published Date: 12/01/2020
Standard Test Method for Measurement of Focal Spots of Industrial X-Ray Tubes by Pinhole Imaging
$17.4
ASTM E749/E749M-17
Published Date: 06/01/2017
Standard Practice for Acoustic Emission Monitoring During Continuous Welding
$14.4

Best-Selling Products

AISI CF03-1
Published Date:
STEEL STUD BRICK VENEER DESIGN GUIDE
AISI CF06-1P
Published Date: 01/01/2004
DIRECT STRENGTH METHOD DESIGN GUIDE (DSM)
AISI CF87-1
Published Date: 01/01/1987
DEVELOPMENT OF A UNIFIED APPROACH TO THE DESIGN OF COLD-FORM
AISI CF92-2
Published Date: 01/01/1992
SHEAR RESISTANCE OF WALLS WITH STEEL STUDS
AISI CF93-1
Published Date: 01/01/1993
PRELIMINARY DESIGN GUIDE FOR COLD-FORMED STEEL C- AND Z-MEMB
AISI D100-08
Published Date: 01/01/2008
2008 Edition of the Cold-Formed Steel Design Manual