1.1 This specification covers the composition, dimensions, and physical properties of compression-resistant, perpendicularly oriented mineral fiber (rock, slag, or glass) roll and sheet insulation intended for use on flat, curved, or round surfaces operating at temperatures between 0°F (-18°C) and 1000°F (538°C). This product (pipe and tank insulation) is typically used on nominal 24 in. (610 mm) or greater diameter surfaces. For specific applications, the actual use temperatures and diameters shall be agreed upon between the manufacturer and the purchaser.

1.2 The orientation of the fibers within the roll or sheet insulation is essentially perpendicular to the heated/cooled surface (parallel to heat flow). This specification does not apply to flat block, board, duct wrap, or preformed pipe mineral fiber insulation where the insulation fiber orientation is generally parallel to the heated/cooled surface (across the heat flow).

1.3 For satisfactory performance, properly installed protective vapor retarders must be used in below ambient temperature applications to reduce movement of moisture/water vapor through or around the insulation towards the colder surface. Failure to use a vapor retarder can lead to insulation and system damage. Refer to Practice C921 to aid material selection. Although vapor retarders properties are not part of this specification, properties required in Specification C1136 are pertinent to application or performance.

1.4 When the installation or use of thermal materials, accessories, and systems may pose safety or health problems, the manufacturer shall provide the user-appropriate current information regarding any known problems associated with the recommended use for the products of the company and shall also recommend protective measures to be employed in their safe utilization. The user shall establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 98 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 01/01/2014
Redline File Size : 2 files , 170 KB

History

ASTM C1393-19
Published Date: 11/01/2019
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$15
ASTM C1393-14(2019)
Published Date: 03/01/2019
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$18
ASTM C1393-14
Published Date: 01/01/2014
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$18
ASTM C1393-11
Published Date: 05/01/2011
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$18
ASTM C1393-08
Published Date: 10/01/2008
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$18
ASTM C1393-00a(2006)e1
Published Date: 09/01/2006
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$18
ASTM C1393-00a(2006)
Published Date: 09/01/2006
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$18
ASTM C1393-00a
Published Date: 01/10/2000
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$18
ASTM C1393-00
Published Date: 01/10/2000
Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks
$17.4

Related products

ASTM C335/C335M-23
Published Date: 03/01/2023
Standard Test Method for Steady-State Heat Transfer Properties of Pipe Insulation
$18.9
ASTM C1363-24
Published Date: 03/01/2024
Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
$29.4
ASTM C612-14(2019)
Published Date: 09/01/2019
Standard Specification for Mineral Fiber Block and Board Thermal Insulation
$15
ASTM C578-23
Published Date: 09/01/2023
Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation
$18.9

Best-Selling Products

IEEE/CABA Smart Grid Research: Connected Homes
Published Date: 05/17/2013
Impact of Smart Grid on Connected Homes Landmark Research Study
$525