ASTM C1590-21 PDF

ASTM C1590-21 PDF

Name:
ASTM C1590-21 PDF

Published Date:
06/01/2021

Status:
Active

Description:

Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-c1590-21_2229371

Choose Document Language:
15.60 €
Need Help?

1.1''This practice provides guidance for an alternate linear calibration for the determination of selected actinide isotopes in appropriately prepared aqueous solutions by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). This alternate calibration is mass bias adjusted using thorium-232 (232Th) and uranium-238 (238U) standards. One of the benefits of this standard practice is the ability to calibrate for the analysis of highly radioactive actinides using calibration standards at much lower specific activities. Environmental laboratories may find this standard practice useful if facilities are not available to handle the highly radioactive standards of the individual actinides of interest.

1.2''The instrument response for a series of determinations of known concentration of'''232Th and'''238U defines the mass versus response relationship. For each standard concentration, the slope of the line defined by'''232Th and''' 238U is used to derive linear calibration curves for each mass of interest using interference equations. The mass bias corrected calibration curves, although generated from interference equations, are specific to the instrument operating parameters and tuning in effect at the time of data acquisition. Because interference equations are part of the normal ICP-MS manufacturer's software package, this calibration methodology is widely applicable.

1.3''For this standard practice, the actinide atomic mass range that has been studied is from AMU 232 to 244. Guidance for an extended range of AMU 228 to 248 is given in this practice.

1.4''Using this practice, analyte concentrations are reported at each AMU and not by element total (that is,'''239Pu versus plutonium).

1.5''The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 110 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 6
Published : 06/01/2021
Redline File Size : 2 files , 220 KB

History

ASTM C1590-21
Published Date: 06/01/2021
Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry
15.60 €
ASTM C1590-04(2014)
Published Date: 01/01/2014
Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry
18.60 €
ASTM C1590-04(2009)
Published Date: 06/01/2009
Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry
18.00 €
ASTM C1590-04
Published Date: 01/01/2004
Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry
17.40 €

Related products

ASTM C752-18
Published Date: 06/01/2018
Standard Specification for Nuclear-Grade Silver-Indium-Cadmium Alloy
12.60 €
ASTM C1463-19
Published Date: 02/01/2019
Standard Practices for Dissolving Glass Containing Radioactive and Mixed Waste for Chemical and Radiochemical Analysis
14.40 €
ASTM C1255-18
Published Date: 06/01/2018
Standard Test Method for Analysis of Uranium and Thorium in Soils by Energy Dispersive X-Ray Fluorescence Spectroscopy
14.40 €
ASTM C1432-23
Published Date: 12/01/2023
Standard Test Method for Determination of Impurities in Plutonium: Acid Dissolution, Ion Exchange Matrix Separation, and Inductively Coupled Plasma-Atomic Emission Spectroscopic (ICP/AES) Analysis
18.90 €

Best-Selling Products

ISO/DIS 10360-5:1998
Published Date: 07/01/1998
Geometrical Product Specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 5: CMMs used with multiple styli
9.90 €
ISO/DIS 11608-3:1998
Published Date: 12/01/1998
Pen-Injectors for Medical Use - Part 3: Finished Cartridges - Requirements and Test Methods
15.30 €
ISO/DIS 11614:1994
Published Date: 05/26/1994
Reciprocating Internal Combustion Compression-Ignition Engines - Apparatus for Measurement of the Opacity and for Determination of the Light Absorption Coefficient of Exhaust Gas - DRAFT
22.50 €
ISO/DIS 1179-2:1995
Published Date: 09/01/1995
Connections for General Use and Fluid Power - Ports and Stud Ends with ISO 228-1 Threads with Elastomeric or Metal-to-Metal Sealing - Part 2: Heavy-Duty (S series) and Light-Duty (L series) Stud Ends with Elastomeric Sealing (type E) (Revision of ISO 1179:1981)
9.90 €
ISO/DIS 1179-3:1995
Published Date: 09/01/1995
Connections for General Use and Fluid Power - Ports and Stud Ends with ISO 228-1 Threads with Elastomeric or Metal-to-Metal Sealing - Part 3: Light-Duty (L series) Stud Ends with Sealing by O-Ring with Retaining Ring (Types G and H) (Revision of ISO 1179:1981)
11.40 €
ISO/DIS 1179-4:1995
Published Date: 09/01/1995
Connections for General Use and Fluid Power - Ports and Stud Ends with ISO 228-1 Threads with Elastomeric or Metal-to-Metal Sealing - Part 4: Stud Ends for General Use Only with Metal-to-Metal Sealing (Type B) (Revision of ISO 1179:1981)
9.90 €