ASTM C1609/C1609M-24 PDF

ASTM C1609/C1609M-24 PDF

Name:
ASTM C1609/C1609M-24 PDF

Published Date:
01/01/2024

Status:
Active

Description:

Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18.9
Need Help?
1.1 This test method evaluates the flexural performance of fiber-reinforced concrete using parameters derived from the load-deflection curve obtained by testing a simply supported beam under third-point loading using a closed-loop, servo-controlled testing system.
1.2 This test method provides for the determination of first-peak and peak loads and the corresponding stresses calculated by inserting them in the formula for modulus of rupture given in Eq 1. It also requires determination of residual loads at specified deflections, the corresponding residual strengths calculated by inserting them in the formula for modulus of rupture given in Eq 1 (see Note 1). It provides for determination of specimen toughness based on the area under the load-deflection curve up to a prescribed deflection (see Note 2) and the corresponding equivalent flexural strength ratio.
Note 1: Residual strength is not a true stress but an engineering stress computed using simple engineering bending theory for linear elastic materials and gross (uncracked) section properties.
Note 2: Specimen toughness expressed in terms of the area under the load-deflection curve is an indication of the energy absorption capability of the particular test specimen, and its magnitude depends directly on the geometry of the test specimen and the loading configuration.
1.3 This test method utilizes two preferred specimen sizes of 100 mm by 100 mm by 350 mm [4 in. by 4 in. by 14 in.] tested on a 300 mm [12 in.] span, or 150 mm by 150 mm by 500 mm [6 in. by 6 in. by 20 in.] tested on a 450 mm [18 in.] span. A specimen size different from the two preferred specimen sizes is permissible.
1.4 Units-The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

File Size : 1 file , 900 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 10
Published : 01/01/2024
Redline File Size : 2 files , 1.4 MB

History

ASTM C1609/C1609M-24
Published Date: 01/01/2024
Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
$18.9
ASTM C1609/C1609M-19a
Published Date: 12/15/2019
Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
$22.5
ASTM C1609/C1609M-19
Published Date: 05/01/2019
Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
$18
ASTM C1609/C1609M-12
Published Date: 12/01/2012
Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
$18
ASTM C1609/C1609M-10
Published Date: 03/01/2010
Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
$18
ASTM C1609/C1609M-07
Published Date: 12/15/2007
Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
$18
ASTM C1609/C1609M-05
Published Date: 12/15/2005
Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading)
$17.4

Related products

ASTM C232/C232M-21
Published Date: 09/01/2021
Standard Test Method for Bleeding of Concrete
$14.4
ASTM C944/C944M-19
Published Date: 10/01/2019
Standard Test Method for Abrasion Resistance of Concrete or Mortar Surfaces by the Rotating-Cutter Method
$15.6
ASTM C1107/C1107M-20
Published Date: 02/01/2020
Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)
$15
ASTM C878/C878M-22
Published Date: 10/15/2022
Standard Test Method for Restrained Expansion of Shrinkage-Compensating Concrete
$17.1

Best-Selling Products