ASTM C1618-13 PDF

ASTM C1618-13 PDF

Name:
ASTM C1618-13 PDF

Published Date:
07/01/2013

Status:
Active

Description:

Standard Test Method for Concrete Sanitary Sewer Pipe by Negative (Vacuum) or Positive Air Pressure

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$15.6
Need Help?

1.1 This test method covers procedures for testing of precast concrete pipe sections, prior to delivery, where maximum field leakage rates are specified.

1.2 Tests described in this standard are intended to be used at the point of manufacture of the concrete pipe and are not intended for testing installed pipe (for field tests see Practices C924, C969, and C1214). The user of this specification is advised that individual or multiple pipe sections may be tested for the purpose of testing the pipe barrel and additionally the joints in straight alignment when multiple pipe sections are tested.

1.3 Test times are based on leakage rates and therefore are proportional only to the pipe diameter and are constant for any length of test pipe or pipeline.

1.4 Test times tabulated and the rate of air loss in this standard are based on successful testing of installed pipelines. However, since air and water have different physical properties, retests of some pipelines not meeting field air tests have been successful when tested with water. The leakage rates of 0.0017 CFM/ft² and 0.0003 CFM/ft², were determined empirically as the maximums for pipe to meet the 50 and 200 gal/(in. of internal diameter) (mile of sewer) (24h) test rates, respectively.

1.5 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

Note 1-The availability of this test procedure for concrete pipe varies from location to location. Check with local supplier(s) for availability and recommendations.

1.6 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish the appropriate safety and health practices and to determine the applicability of regulatory limitations prior to its use. See Section 6 for specific safety precautions.


File Size : 1 file , 62 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 3
Published : 07/01/2013
Redline File Size : 2 files , 120 KB

History

ASTM C1618-19
Published Date: 01/01/2019
Standard Test Method for Concrete Sanitary Sewer Pipe by Negative (Vacuum) Air Pressure
$12.6
ASTM C1618-13
Published Date: 07/01/2013
Standard Test Method for Concrete Sanitary Sewer Pipe by Negative (Vacuum) or Positive Air Pressure
$15.6
ASTM C1618-05(2013)
Published Date: 02/01/2013
Standard Test Method for Concrete Sanitary Sewer Pipe by Negative (Vacuum) or Positive Air Pressure
$15.6

Related products

ASTM E519/E519M-22
Published Date: 12/01/2022
Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages
$17.1
ASTM D3639/D3639M-92(2019)
Published Date: 04/15/2019
Standard Test Method for Classification of Asbestos by Quebec Standard Test (Withdrawn 2022)
$16.8
ASTM C1019-24
Published Date: 06/01/2024
Standard Test Method for Sampling and Testing Grout for Masonry
$18.9
ASTM C425-22
Published Date: 04/01/2022
Standard Specification for Compression Joints for Vitrified Clay Pipe and Fittings
$14.4

Best-Selling Products

VDI/VDE/GESA 2635 Sheet 2
Published Date: 01/01/2004
Experimental structural analysis - Recommended practice for high-temperature strain measurements
VDI/VDE/GESA 2636
Published Date: 10/01/2000
Certification of courses and examinations in strain gage measurement technology