ASTM C1678-09 PDF

ASTM C1678-09 PDF

Name:
ASTM C1678-09 PDF

Published Date:
05/01/2009

Status:
Active

Description:

Standard Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.1
Need Help?

1.1 This practice pertains to the analysis and interpretation of fracture mirror sizes in brittle materials. Fracture mirrors (Fig. 1) are telltale fractographic markings that surround a fracture origin in brittle materials. The fracture mirror size may be used with known fracture mirror constants to estimate the stress in a fractured component. Alternatively, the fracture mirror size may be used in conjunction with known stresses in test specimens to calculate fracture mirror constants. The practice is applicable to glasses and polycrystalline ceramic laboratory test specimens as well as fractured components. The analysis and interpretation procedures for glasses and ceramics are similar, but they are not identical. Different optical microscopy examination techniques are listed and described, including observation angles, illumination methods, appropriate magnification, and measurement protocols. Guidance is given for calculating a fracture mirror constant and for interpreting the fracture mirror size and shape for both circular and noncircular mirrors including stress gradients, geometrical effects, and/or residual stresses. The practice provides figures and micrographs illustrating the different types of features commonly observed in and measurement techniques used for the fracture mirrors of glasses and polycrystalline ceramics.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note - The initial flaw may grow stably to size ac prior to unstable fracture when the stress intensity reaches KIc. The mirror-mist radius is Ri, the mist-hackle radius is Ro, and the branching distance is Rb. These transitions correspond to the mirror constants, Ai, Ao, and Ab, respectively.


FIG. 1 Schematic of a Fracture Mirror Centered on a Surface Flaw of Initial Size (a).


File Size : 1 file , 820 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 15
Published : 05/01/2009
Redline File Size : 2 files , 1.6 MB

History

ASTM C1678-21
Published Date: 07/01/2021
Standard Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses
$20.7
ASTM C1678-10
Published Date: 01/01/2010
Standard Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses
$20.1
ASTM C1678-09
Published Date: 05/01/2009
Standard Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses
$20.1
ASTM C1678-07
Published Date: 10/15/2007
Standard Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses
$19.5

Related products

ASTM C1494-13(2024)
Published Date: 09/01/2024
Standard Test Methods for Determination of Mass Fraction of Carbon, Nitrogen, and Oxygen in Silicon Nitride Powder
$18.9
ASTM D3466-06(2023)
Published Date: 12/01/2023
Standard Test Method for Ignition Temperature of Granular Activated Carbon
$16.5
ASTM C492-92(2023)
Published Date: 11/01/2023
Standard Test Method for Hydration of Granular Dead-Burned Refractory Dolomite
$16.5
ASTM C544-18(2023)
Published Date: 11/01/2023
Standard Test Method for Hydration of Dead-Burned Magnesite or Periclase Grain
$16.5

Best-Selling Products