ASTM D2161-20 PDF

ASTM D2161-20 PDF

Name:
ASTM D2161-20 PDF

Published Date:
12/01/2020

Status:
Active

Description:

Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$22.5
Need Help?

1.1''This practice2 covers the conversion tables and equations for converting kinematic viscosity in mm²/s at any temperature to Saybolt Universal viscosity in Saybolt Universal seconds (SUS) at the same temperature and for converting kinematic viscosity in mm²/s at 122'''''F and 210'''''F (50'''''C and 98.9'''''C) to Saybolt Furol viscosity in Saybolt Furol seconds (SFS) at the same temperatures. Kinematic viscosity values are based on water being 1.0034'''mm²/s (cSt) at 68'''''F (20'''''C).

1.2''If a method other than Test Method D445 is used to generate the kinematic viscosity data, apply appropriate relative-bias correction factors as found in the precision section of that method, before performing the calculations of this practice.

Note 1:''The equations in D2161 were originally empirically derived using data from both D445 and the Saybolt viscometer method. Therefore, it is conceivable that an error could result if the kinematic viscosities used are not bias-corrected to D445 results. It is recommended that kinematic viscosity be reported in millimetres squared per second, instead of Saybolt Universal Seconds (SUS) or Saybolt Furol Seconds (SFS). This method is being retained for the purpose of calculation of kinematic viscosities from SUS and SFS data that appear in past literature. One millimetre squared per second (mm²/s) equals one centistoke (cSt), which is another unit commonly found in older literature.

1.3''The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for reference information purposes only. The SI unit of kinematic viscosity is mm²/s.

1.3.1''Exception'''Fahrenheit temperature units are used in this practice because they are accepted by industry for the type of legacy conversions described in this practice.

1.4''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 170 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 26
Published : 12/01/2020
Redline File Size : 2 files , 310 KB

History

ASTM D2161-20
Published Date: 12/01/2020
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$22.5
ASTM D2161-19
Published Date: 05/01/2019
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$26.7
ASTM D2161-17
Published Date: 07/01/2017
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$25.8
ASTM D2161-10
Published Date: 10/01/2010
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$25.8
ASTM D2161-05e1
Published Date: 04/01/2005
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$25.8
ASTM D2161-05
Published Date: 04/01/2005
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$25.8
ASTM D2161-04
Published Date: 12/01/2004
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$25.8
ASTM D2161-93(1999)e2
Published Date: 01/01/1999
Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$25.8
ASTM D2161-82
Published Date: 01/01/1982
Standard Method for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
$25.8
ASTM D2161-66
Published Date: 01/01/1966
Standard Method Of Test For Conversion Of Kinematic Viscosity To Saybolt Universal Viscosity Or To Saybolt Furol Viscosity
$21.3

Related products

ASTM D1550-18
Published Date: 10/01/2018
Standard ASTM Butadiene Measurement Tables
$16.2
ASTM D2162-21
Published Date: 04/01/2021
Standard Practice for Basic Calibration of Master Viscometers and Viscosity Oil Standards
$15.6

Best-Selling Products