Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-d3739-19_2077921

Choose Document Language:
13.20 €
Need Help?

1.1 This practice covers the calculation and adjustment of the Langelier saturation index for the concentrate stream of a reverse osmosis (RO) device. This index is used to determine the need for calcium carbonate (CaCo3) scale control in the operation and design of RO installations. This practice is applicable for concentrate streams containing 10 to 10 000 mg/L of total dissolved solids. For concentrate containing over 10 000 mg/L, see Practice D4582.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 230 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 4
Published : 07/01/2019

History

ASTM D3739-19
Published Date: 07/01/2019
Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
13.20 €
ASTM D3739-06(2010)
Published Date: 05/01/2010
Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis (Withdrawn 2019)
15.60 €
ASTM D3739-05
Published Date: 01/01/2005
Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
15.60 €
ASTM D3739-94(2003)
Published Date: 06/10/2003
Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
15.60 €
ASTM D3739-94(1998)
Published Date: 12/10/1998
Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
15.00 €

Related products

ASTM D4517-15(2023)
Published Date: 04/01/2023
Standard Test Method for Low-Level Total Silica in High-Purity Water by Flameless Atomic Absorption Spectroscopy
17.10 €
ASTM D5811-20
Published Date: 05/01/2020
Standard Test Method for Strontium-90 in Water
15.00 €
ASTM D4025-18
Published Date: 05/01/2018
Standard Practice for Reporting Results of Examination and Analysis of Deposits Formed from Water for Subsurface Injection
12.60 €

Best-Selling Products