ASTM D5466-01 PDF

ASTM D5466-01 PDF

Name:
ASTM D5466-01 PDF

Published Date:
12/10/2001

Status:
Active

Description:

Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$25.8
Need Help?

1.1 This test method describes a procedure for sampling and analysis of volatile organic compounds (VOCs) in ambient, indoor, or workplace atmospheres. The test method is based on the collection of air samples in stainless steel canisters with specially treated (passivated) interior surfaces. For sample analysis, a portion of the sample is subsequently removed from the canister and the collected VOCs are selectively concentrated by adsorption or condensation onto a trap, subsequently released by thermal desorption, separated by gas chromatography, and measured by a mass spectrometric detector or other detector(s). This test method describes procedures for sampling into canisters to final pressures both above and below atmospheric pressure (respectively referred to as pressurized and subatmospheric pressure sampling).

1.2 This test method is applicable to specific VOCs that have been tested and determined to be stable when stored in canisters. Numerous compounds, many of which are chlorinated VOCs, have been successfully tested for storage stability in pressurized canisters (1-4). Although not as extensive, documentation is also available demonstrating stability of VOCs in subatmospheric pressure canisters. While initial studies were concentrated on non-polar VOCs, information on storage stability has been extended to many polar compounds as well (5-7).

1.3 The procedure for collecting the sample involves the use of inlet lines and air filters, flow rate regulators for obtaining time-integrated samples, and in the case of pressurized samples, an air pump. Canister samplers have been designed to automatically start and stop the sample collection process using electronically actuated valves and timers (8-10). A weatherproof shelter is required if the sampler is to be used outside.

1.4 The organic compounds that have been successfully measured at single-digit parts-per-billion by volume (ppbv) levels with this test method are listed in . This test method is applicable to VOC concentrations ranging from the detection limit to 300 ppbv. Above this concentration, samples require dilution with dry ultra-high-purity nitrogen or air.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Safety practices should be part of the user's SOP manual.


File Size : 1 file , 300 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 21
Published : 12/10/2001

History

ASTM D5466-21
Published Date: 08/14/2021
Standard Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling, Mass Spectrometry Analysis Methodology)
$22.5
ASTM D5466-01(2007)
Published Date: 04/01/2007
Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology)
$25.8
ASTM D5466-01
Published Date: 12/10/2001
Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology)
$25.8
ASTM D5466-95
Published Date: 01/01/1995
Standard Test Method for Determination of Volatile Organic Chemicals in Atmospheres (Canister Sampling Methodology)
$24.9

Related products

ASTM D3670-91(2022)
Published Date: 08/31/2022
Standard Guide for Determination of Precision and Bias of Methods of Committee D22
$17.1
ASTM D5014-94(2000)e1
Published Date: 03/10/2000
Standard Test Method for Measurement of Formaldehyde in Indoor Air (Passive Sampler Methodology) (Withdrawn 2006)
$17.4
ASTM D6281-23
Published Date: 09/01/2023
Standard Test Method for Airborne Asbestos Concentration in Ambient and Indoor Atmospheres as Determined by Transmission Electron Microscopy Direct Transfer (TEM)
$24.6
ASTM E2250-02
Published Date: 10/10/2002
Standard Method for Determination of Endotoxin Concentration in Water Miscible Metal Working Fluids (Withdrawn 2008)
$15

Best-Selling Products

CAN/CSA 2/1/9075
Published Date: 03/01/2002
Information Technology - Database Languages - SQL - Part 2: Foundation (SQL/Foundation) (Adopted ISO/IEC 9075-2:1999, first edition, 1999-12-01)
$88.5
CAN/CSA 50001:11 (R2016)
Published Date: 06/01/2011
Energy management systems - Requirements with guidance for use (Adopted ISO 50001:2011, first edition, 2011-06-15)
$33
CAN/CSA 6.19-01 (R2016)
Published Date: 10/03/2001
Residential Carbon Monoxide Alarming Devices
$101.7
CAN/CSA 601.2.1-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Medical Electron Accelerators in the Range 1 MeV to 50 MeV (Adopted IEC 601-2-1:1981)
$14.1
CAN/CSA 601.2.11-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Gamma Beam Therapy Equipment (Adopted IEC 601- 2-11:1987)
$14.1
CAN/CSA 601.2.14-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Electroconvulsive Therapy Equipment (Adopted IEC 601-2-14:1989)
$11.1