ASTM D5790-18 PDF

ASTM D5790-18 PDF

Name:
ASTM D5790-18 PDF

Published Date:
12/15/2018

Status:
Active

Description:

Standard Test Method for Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$24.6
Need Help?

1.1 This test method covers the identification and simultaneous measurement of purgeable volatile organic compounds. It has been validated for treated drinking water, wastewater, and ground water. This test method is not limited to these particular aqueous matrices; however, the applicability of this test method to other aqueous matrices must be demonstrated.

1.2 This test method is applicable to a wide range of organic compounds that have sufficiently high volatility and low water solubility to be efficiently removed from water samples using purge and trap procedures. Table 1 lists the compounds that have been validated for this test method. This test method is not limited to the compounds listed in Table 1; however, the applicability of the test method to other compounds must be demonstrated.

1.3 Analyte concentrations up to approximately 200 μg/L may be determined without dilution of the sample. Analytes that are inefficiently purged from water will not be detected when present at low concentrations, but they can be measured with acceptable accuracy and precision when present in sufficient amounts.

1.4 Analytes that are not separated chromatographically, but that have different mass spectra and non-interfering quantitation ions, can be identified and measured in the same calibration mixture or water sample. Analytes that have very similar mass spectra cannot be individually identified and measured in the same calibration mixture or water sample unless they have different retention times. Coeluting compounds with very similar mass spectra, such as structural isomers, must be reported as an isomeric group or pair. Two of the three isomeric xylenes are examples of structural isomers that may not be resolved on the capillary column, and if not, must be reported as an isomeric pair.

1.5 It is the responsibility of the user to ensure the validity of this test method for untested matrices.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 320 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 64
Published : 12/15/2018
Redline File Size : 2 files , 640 KB

History

ASTM D5790-18
Published Date: 12/15/2018
Standard Test Method for Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry
$24.6
ASTM D5790-95(2012)
Published Date: 06/15/2012
Standard Test Method for Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry
$28.2
ASTM D5790-95(2006)
Published Date: 02/15/2006
Standard Test Method for Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry
$28.2
ASTM D5790-95(2001)
Published Date: 01/01/1995
Standard Test Method for Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry
$28.2
ASTM D5790-95
Published Date: 01/01/1995
Standard Test Method for Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry
$27.3

Related products

ASTM D5217-17
Published Date: 11/01/2017
Standard Guide for Detection of Fouling and Degradation of Particulate Ion Exchange Materials
$14.4
ASTM D4025-18
Published Date: 05/01/2018
Standard Practice for Reporting Results of Examination and Analysis of Deposits Formed from Water for Subsurface Injection
$12.6
ASTM D3084-20
Published Date: 07/01/2020
Standard Practice for Alpha-Particle Spectrometry of Water
$15.6
ASTM D7284-20
Published Date: 08/01/2020
Standard Test Method for Total Cyanide in Water by Micro Distillation followed by Flow Injection Analysis with Gas Diffusion Separation and Amperometric Detection
$15

Best-Selling Products

SAIA A92.10-2009
Published Date: 10/13/2009
Transport Platforms
$16.5
SAIA A92.2-2001
Published Date: 02/01/2002
Vehicle-Mounted Elevating and Rotating Aerial Devices
$16.5
SAIA A92.2-2009
Published Date: 09/01/2009
Vehicle-Mounted Elevating and Rotating Aerial Platforms
$16.5
SAIA A92.2-2021
Published Date:
Vehicle-Mounted Elevating and Rotating Aerial Devices
$17.7
SAIA A92.20-2018
Published Date: 12/10/2018
Design, Calculations, Safety Requirements and Test Methods for Mobile Elevating Work Platforms (MEWPs)
$40.5
SAIA A92.20-2020
Published Date: 06/01/2020
Design, Calculations, Safety Requirements and Test Methods for Mobile Elevating Work Platforms (MEWPs)
$40.5