ASTM D5812-96(2002)e1 PDF

ASTM D5812-96(2002)e1 PDF

Name:
ASTM D5812-96(2002)e1 PDF

Published Date:
05/10/1996

Status:
[ Withdrawn ]

Description:

Standard Test Method for Determination of Organochlorine Pesticides in Water by Capillary Column Gas Chromatography (Withdrawn 2011)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-d5812-96-2002-e1_2415

Choose Document Language:
20.10 €
Need Help?

1.1 This test method covers the capillary gas chromatographic determination of various organochlorine pesticides, including some of their degradation products and related compounds in finished drinking water. This test method is not limited to this particular aqueous matrix; however, its applicability to other aqueous matrices must be determined. The tested compounds include the following:

Numbering system of CAS Registry Services, P.O. Box 3343, Columbus, OH 43210-0334.

PesticideChemical Abstract Service Registry Number Aldrin309-00-2-BHC319-84-6-BHC319-85-7-BHC319-86-8-BHC58-89-9-Chlordane5103-71-9-Chlordane5103-74-2Chlorobenzilate501-15-6Chloroneb2675-77-6Chlorothalonil2921-88-2DCPA1897-45-64,4`-DDD72-54-84,4`-DDE72-55-94,4`-DDT50-29-3Dieldrin60-57-1Endosulfan I959-98-8Endosulfan II33213-65-9Endosulfan sulfate1031-0708Endrin72-20-8Endrin aldehyde7421-93-4Etridiazole2593-15-9Heptachlor76-44-8Heptachlor epoxide1024-57-3Hexachlorobenzene118-74-1Methoxychlor72-43-5cis-Permethrin52645-53-1trans-Permethrin52645-53-1Propachlor1918-16-7Trifluralin1582-09-8

1.2 and list the applicable concentration ranges and precision and bias statements for this test method. The applicability of this test method to other compounds must be demonstrated.

1.3 The extract derived from this procedure may be analyzed for these constituents by using the gas chromatography (GC) conditions prescribed in Test Method D 5175 (capillary column). Although the columns used in this test method may be adequate for analyzing PCBs, no data were collected for any multi-congener constituents during methods development.

1.4 This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results using the procedures described in Section 12.

1.5 Analytes that are not separated chromatographically by either the primary or secondary chromatographic columns (for example, analytes having very similar retention times) cannot be identified and measured individually in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exists (see 7.9 and 13.4).

1.6 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications and concentrations should be confirmed by at least one additional technique.

1.7 The values stated in SI units are to be regarded as the standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 9.


File Size : 1 file , 130 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 12
Published : 05/10/1996

History


Related products

ASTM D5615-23
Published Date: 11/01/2023
Standard Practice for Operating Characteristics of Home Reverse Osmosis Devices
16.50 €
ASTM D5074-90(2022)
Published Date: 05/01/2022
Standard Practice for Preparation of Natural-Matrix Sediment Reference Samples for Major and Trace Inorganic Constituents Analysis by Partial Extraction Procedures
14.40 €
ASTM D4136-82(2012)
Published Date: 09/01/2012
Standard Practice for Sampling Phytoplankton with Water-Sampling Bottles (Withdrawn 2020)
15.60 €
ASTM D7903-14(2020)
Published Date: 11/01/2020
Standard Practice for Determining the Capacity of Oxygen Removal Ion Exchange Cartridges
13.80 €

Best-Selling Products

DRM ASME B31.3 & GUIDE SET
Published Date: 01/01/2000
ASME PROCESS PIPING / PROCESS PIPING: THE COMPLETE GUIDE TO ASME B31.3 SET (ASME B31.3 & ASME B31.3 GUIDE) - YOU SAVE 10% ***INCLUDES B31.3-2020 EDITION***
160.50 €
DRM ASME B31.8 PIPING SET
Published Date: 01/01/2000
ASME GAS TRANSMISSION PIPING SET - INCLUDES ASME B31.8, ASME B31.8S, ASME B31.1, ASME B31.3 AND ASME B31.3 GUIDE - YOU SAVE 10%
364.50 €
DRM DEEPWATER SET
Published Date: 01/01/2000
DEEPWATER SET INCLUDES THE FOLLOWING STANDARDS: API RP 14J, API RP 2A-WSD, API RP 2FPS, API RP 2RD, API RP 2SK, API RP 2SM, API RP 2T, API SPEC 17J, AWS D3.6M
274.50 €
DRM DRM COMBO
Published Date: 01/01/2008
Drawing Requirements Manual (Hardcopy Bound & DVD)
157.50 €
DRM DRM DVD
Published Date: 01/01/2008
Drawing Requirements Manual DVD
104.70 €
DRM DRM
Published Date: 01/01/2008
DRAWING REQUIREMENTS MANUAL
104.70 €