1.1 This field test method employs an extractive sampling system to direct stationary source effluent to an FTIR spectrometer for the identification and quantification of gaseous compounds. This test method is potentially applicable for the determination of compunds that (1) have sufficient vapor pressure to be transported to the FTIR spectrometer and (2) absorb a sufficient amount of infrared radiation to be detected.

1.2 This field test method provides near real time analysis of extracted gas samples from stationary sources. Gas streams with high moisture content may require conditioning to minimize the excessive spectral absorption features imposed by water vapor.

1.3 This field test method requires the preparation of a source specific field test plan. The test plan must include the following: (1) the identification of the specific target analytes (2) the known analytical interferents specific to the test facility source effluent (3) the test data quality necessary to meet the specific test requirements and (4) the results obtained from the laboratory testing (see Annex A1 for test plan requirements).

1.4 The FTIR instrument range should be sufficient to measure from high ppm(v) to ppb(v) and may be extended to higher or lower concentrations using any or all of the following procedures:

1.4.1 The gas absorption cell path length may be either increased or decreased,

1.4.2 The sample conditioning system may be modified to reduce the water vapor, CO2, and other interfering compounds to levels that allow for quantification of the target compound(s), and

1.4.3 The analytical method may be modified such that interfering absorbance bands are minimized or stronger/weaker absorbance bands are employed for the target analytes.

1.5 The practical minimum detectable concentration is instrument, compound, and interference specific (see Annex A2 for procedures to estimate the achievable minimum detectable concentrations (MDCs)). Detection limits in the parts per billion range are possible; however, the actual sensitivity of the FTIR measurement system for the individual target analytes depends upon the following:

1.5.1 The specific infrared absorptivity (signal) and wavelength analysis region for each target analyte,

1.5.2 The amount of instrument noise (see Annex A6), and

1.5.3 The concentration of interfering compounds in the sample gas (in particular, percent moisture and CO2), and the amount of spectral overlap imparted by these compounds in the wavelength region(s) used for the quantification of the target analytes.

1.6 Practices E 168 and E 1252 are suggested for additional reading.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Additional safety precautions are described in Section 9.


File Size : 1 file , 160 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 13
Published : 12/10/1998

History

ASTM D6348-12(2020)
Published Date: 12/01/2020
Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy
76.00 58.00 you save 18.00
ASTM D6348-12e1
Published Date: 02/01/2012
Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy
$20.7
ASTM D6348-12
Published Date: 02/01/2012
Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy
$20.1
ASTM D6348-03(2010)
Published Date: 10/01/2010
Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy
$20.1
ASTM D6348-03
Published Date: 10/01/2003
Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy
$20.1
ASTM D6348-98
Published Date: 12/10/1998
Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy
$19.5

Related products

ASTM F778-88(2023)
Published Date: 01/01/2023
Standard Methods for Gas Flow Resistance Testing of Filtration Media
76.00 63.00 you save 13.00
ASTM D6177-19(2024)
Published Date: 09/01/2024
Standard Practice for Determining Emission Profiles of Volatile Organic Chemicals Emitted from Bedding Sets
$16.5
ASTM F1868-23
Published Date: 06/01/2023
Standard Test Method for Thermal Resistance, Evaporative Resistance, and Total Heat Loss Measurements of Clothing Materials Using a Sweating Hot Plate
$17.1
ASTM F2053-00(2023)
Published Date: 06/01/2023
Standard Guide for Documenting the Results of Airborne Particle Penetration Testing of Protective Clothing Materials
$17.1

Best-Selling Products

TCA CTI 2012
Published Date: 2012
2012 TCA Handbook for Ceramic, Glass, and Stone Tile Installation
$12.6
TCA CTI 2013
Published Date: 2013
2013 TCNA Handbook for Ceramic, Glass, and Stone Tile Installation - Version 2013.1
TCA CTI
Published Date: 01/01/2008
2008 TCA Handbook for Ceramic Tile Installation
TCA CTI
Published Date: 2009
2009 TCA Handbook for Ceramic Tile Installation
TCA CTI
Published Date: 2010
2010 TCA Handbook for Ceramic Tile Installation
TCA CTI
Published Date: 2011
2011 TCA Handbook for Ceramic, Glass, and Stone Tile Installation