ASTM D6512-07(2014) PDF

ASTM D6512-07(2014) PDF

Name:
ASTM D6512-07(2014) PDF

Published Date:
01/15/2014

Status:
[ Withdrawn ]

Description:

Standard Practice for Interlaboratory Quantitation Estimate (Withdrawn 2023)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$22.8
Need Help?

1.1 This practice establishes a uniform standard for computing the interlaboratory quantitation estimate associated with Z % relative standard deviation (referred to herein as IQEZ %), and provides guidance concerning the appropriate use and application. The calculations involved in this practice can be performed with DQCALC, Microsoft Excel-based software available from ASTM.2

1.2 IQEZ % is computed to be the lowest concentration for which a single measurement from a laboratory selected from the population of qualified laboratories represented in an interlaboratory study will have an estimated Z % relative standard deviation (Z % RSD, based on interlaboratory standard deviation), where Z is typically an integer multiple of 10, such as 10, 20, or 30, but Z can be less than 10. The IQE10 % is consistent with the quantitation approaches of Currie (1)3 and Oppenheimer, et al. (2).

1.3 The fundamental assumption of the collaborative study is that the media tested, the concentrations tested, and the protocol followed in the study provide a representative and fair evaluation of the scope and applicability of the test method as written. Properly applied, the IQE procedure ensures that the IQE has the following properties:

1.3.1 Routinely Achievable IQE Value-Most laboratories are able to attain the IQE quantitation performance in routine analyses, using a standard measurement system, at reasonable cost. This property is needed for a quantitation limit to be feasible in practical situations. Representative laboratories must be included in the data to calculate the IQE.

1.3.2 Accounting for Routine Sources of Error-The IQE should realistically include sources of bias and variation that are common to the measurement process. These sources include, but are not limited to: intrinsic instrument noise, some “typical” amount of carryover error; plus differences in laboratories, analysts, sample preparation, and instruments.

1.3.3 Avoidable Sources of Error Excluded-The IQE should realistically exclude avoidable sources of bias and variation; that is, those sources that can reasonably be avoided in routine field measurements. Avoidable sources would include, but are not limited to: modifications to the sample; modifications to the measurement procedure; modifications to the measurement equipment of the validated method, and gross and easily discernible transcription errors, provided there was a way to detect and either correct or eliminate them.

1.4 The IQE applies to measurement methods for which calibration error is minor relative to other sources, such as when the dominant source of variation is one of the following:

1.4.1 Sample Preparation, and calibration standards do not have to go through sample preparation.

1.4.2 Differences in Analysts, and analysts have little opportunity to affect calibration results (as is the case with automated calibration).

1.4.3 Differences in Laboratories  (for whatever reasons), perhaps difficult to identify and eliminate.

1.4.4 Differences in Instruments  (measurement equipment), such as differences in manufacturer, model, hardware, electronics, sampling rate, chemical processing rate, integration time, software algorithms, internal signal processing and thresholds, effective sample volume, and contamination level.

1.5 Data Quality Objectives-Typically, one would compute the lowest % RSD possible for any given dataset for a particular method. Thus, if possible, IQE10 % would be computed. If the data indicated that the method was too noisy, one might have to compute instead IQE20 %, or possibly IQE30 %. In any case, an IQE with a higher % RSD level (such as IQE50 %) would not be considered, though an IQE with RSD <10 % (such as IQE1 % ) would be acceptable. The appropriate level of % RSD may depend on the intended use of the IQE.


File Size : 1 file , 240 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 15
Published : 01/15/2014

History

ASTM D6512-07(2014)
Published Date: 01/15/2014
Standard Practice for Interlaboratory Quantitation Estimate (Withdrawn 2023)
$22.8
ASTM D6512-07
Published Date: 03/01/2007
Standard Practice for Interlaboratory Quantitation Estimate
$20.1
ASTM D6512-03
Published Date: 03/10/2003
Standard Practice for Interlaboratory Quantitation Estimate
$20.1
ASTM D6512-00
Published Date: 02/10/2000
Standard Practice for Interlaboratory Quantitation Estimate
$19.5

Related products

ASTM D3645-15(2023)
Published Date: 12/01/2023
Standard Test Methods for Beryllium in Water
$18.9
ASTM D5906-21
Published Date: 11/01/2021
Standard Guide for Measuring Horizontal Positioning During Measurements of Surface Water Depths
$18
ASTM D1129-13(2020)e2
Published Date: 05/01/2020
Standard Terminology Relating to Water
$31.5
ASTM D1429-13
Published Date: 06/01/2013
Standard Test Methods for Specific Gravity of Water and Brine (Withdrawn 2022)
$19.2

Best-Selling Products

CLSI AUTO01-A
Published Date: 12/20/2000
Laboratory Automation: Specimen Container/Specimen Carrier; Approved Standard, AUTO01AE
$54
CLSI AUTO02-A2
Published Date: 01/05/2006
Laboratory Automation: Bar Codes for Specimen Container Identification; Approved Standard, AUTO02A2E
$54
CLSI AUTO03-A2
Published Date: 09/01/2009
Laboratory Automation: Communications with Automated Clinical Laboratory Systems, Instruments, Devices, and Information Systems; Approved Standard, Second Edition, AUTO03A2
$54
CLSI AUTO04-A
Published Date: 03/20/2001
Laboratory Automation: Systems Operational Requirements, Characteristics, and Information Elements; Approved Standard, AUTO04AE
CLSI AUTO05-A
Published Date: 03/20/2001
Laboratory Automation: Electromechanical Interfaces; Approved Standard, AUTO05AE
CLSI AUTO07-A
Published Date: 06/20/2004
Laboratory Automation: Data Content for Specimen Identification; Approved Standard, AUTO07AE