ASTM D6841-21 PDF

ASTM D6841-21 PDF

Name:
ASTM D6841-21 PDF

Published Date:
06/01/2021

Status:
Active

Description:

Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-Retardant-Treated Lumber

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$15.6
Need Help?

1.1''This practice covers procedures for calculating adjustment factors that account for the effects of fire-retardant treatment on design properties of lumber. The adjustment factors calculated in accordance with this practice are to be applied to design values for untreated lumber in order to determine design values for fire-retardant-treated lumber used at ambient temperatures [service temperatures up to 100 ''F (38 ''C)] and as framing in roof systems.

Note 1:''This analysis focuses on the relative performance of treated and untreated materials tested after equilibrating to ambient conditions following a controlled exposure to specified conditions of high temperature and humidity. Elevated temperature, moisture, load duration, and other factors typically accounted for in the design of untreated lumber must also be considered in the design of fire-retardant-treated lumber, but are outside the scope of the treatment adjustments developed under this practice.

1.2''These adjustment factors for the design properties in bending, tension parallel to grain, compression parallel to grain, horizontal shear, and modulus of elasticity are based on the results of strength tests of matched treated and untreated small clear wood specimens after conditioning at nominal room temperatures [72 ''F (22 ''C)] and of other similar specimens after exposure at 150 ''F (66 ''C). The test data are developed in accordance with Test Method D5664. Guidelines are provided for establishing adjustment factors for the property of compression perpendicular to grain and for connection design values.

1.3''Treatment adjustment factors for roof framing applications are based on thermal load profiles for normal wood roof construction used in a variety of climates as defined by weather tapes of the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE).2 The solar loads, moisture conditions, ventilation rates, and other parameters used in the computer model were selected to represent typical sloped roof designs. The thermal loads in this practice are applicable to roof slopes of 3 in 12 or steeper, to roofs designed with vent areas and vent locations conforming to national standards of practice and to designs in which the bottom side of the roof sheathing is exposed to ventilation air. For designs that do not have one or more of these base-line features, the applicability of this practice needs to be documented by the user.

1.4''The procedures of this practice parallel those given in Practice D6305. General references and commentary in Practice D6305 are also applicable to this practice.

1.5''The values stated in inch-pound units are to be regarded as standard. The SI units listed in parentheses are provided for information only and are not considered standard.

1.6''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 180 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 7
Published : 06/01/2021
Redline File Size : 2 files , 440 KB

History

ASTM D6841-21
Published Date: 06/01/2021
Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-Retardant-Treated Lumber
$15.6
ASTM D6841-08
Published Date: 09/01/2008
Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-Retardant-Treated Lumber
$18
ASTM D6841-03
Published Date: 11/10/2003
Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-Retardant-Treated Lumber
$18
ASTM D6841-02
Published Date: 11/10/2002
Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-Retardant-Treated Lumber
$17.4

Related products

ASTM D1628-94(2000)
Published Date: 01/10/2000
Standard Test Methods for Chemical Analysis of Chromated Copper Arsenate (Withdrawn 2006)
$15
ASTM D1036-99(2017)
Published Date: 10/01/2017
Standard Test Methods of Static Tests of Wood Poles
$16.2
ASTM D5664-17
Published Date: 04/15/2017
Standard Test Method for Evaluating the Effects of Fire-Retardant Treatments and Elevated Temperatures on Strength Properties of Fire-Retardant Treated Lumber
$14.4
ASTM D5456-21e1
Published Date: 02/01/2021
Standard Specification for Evaluation of Structural Composite Lumber Products
$24.6

Best-Selling Products

ANSI/IEC 60529-2004 (R2011)
Published Date: 2004
Degrees of Protection Provided by Enclosures (IP Code)
$42
ANSI/IEC 60529-2020
Published Date: 2020
Degrees of Protection Provided by Enclosures (IP Code)(Identical National Adoption)
$81.6
ANSI/IEC 60974-1-2008
Published Date: 2008
American National Standard for Arc-Welding Equipment - Part 1: Welding Power Sources
$67.2
ANSI/IEC 60974-1-2019 (R2023)
Published Date: 12/13/2019
American National Standard for Arc-Welding Equipment - Part 1: Welding Power Sources
$138.6
ANSI/IEC 60974-11-2009 (R2020)
Published Date: 2009
American National Standard for Arc-Welding Equipment -- Part 11: Electrode Holders
$27.9
ANSI/IEC 60974-12-2009 (R2020)
Published Date: 2009
American National Standard for Arc-Welding Equipment -- Part 12: Coupling Devices for Welding Cables
$81.3