Standard Test Method for Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18
Need Help?

1.1 This test method is used to establish the concentration of free cyanide in an aqueous wastewater or effluent. The test conditions of this method are used to measure free cyanide (HCN and CN-) and cyanide bound in the metal-cyanide complexes that are easily dissociated into free cyanide ions at the pH of 6. Free cyanide is determined at pH 6 at room temperature. The aquatic free cyanide can be determined by matching the pH to the water in the receiving environment in the range of pH 6 to 8. The extent of HCN formation is less dependent on temperature than the pH; however, the temperature can be regulated if deemed necessary for aquatic free cyanide to further simulate the actual aquatic environment.

1.2 The free cyanide method is based on the same instrumentation and technology that is described in standard test method D6888, but employs milder conditions (pH 6-8 buffer versus HCl or H2SO4 in the reagent stream), and does not utilize ligand displacement reagents.

1.3 The aquatic free cyanide measured by this procedure should be similar to actual levels of HCN in the original aquatic environment. This in turn may give a reliable index of toxicity to aquatic organisms.

1.4 This procedure is applicable over a range of approximately 2 to 500 μg/L (parts per billion) free cyanide. Sample dilution may increase cyanide recoveries depending on the cyanide speciation; therefore, it is not recommended to dilute samples. Higher concentrations can be analyzed by increasing the range of calibration standards or with a lower injection volume. In accordance with Guide E1763 and Practice D6512 the lower scope limit was determined to be 9 μg/L for chlorinated gold leaching barren effluent water.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 8.6 and Section 9.


File Size : 1 file , 130 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 8
Published : 05/01/2010
Redline File Size : 2 files , 270 KB

History

ASTM D7237-18
Published Date: 12/01/2018
Standard Test Method for Free Cyanide and Aquatic Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection
$17.4
ASTM D7237-10
Published Date: 05/01/2010
Standard Test Method for Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection
$18
ASTM D7237-06
Published Date: 02/01/2006
Standard Test Method for Aquatic Free Cyanide with Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection
$17.4

Related products

ASTM D3326-07(2024)
Published Date: 04/01/2024
Standard Practice for Preparation of Samples for Identification of Waterborne Oils
$18.9
ASTM D4839-03(2024)
Published Date: 04/01/2024
Standard Test Method for Total Carbon and Organic Carbon in Water by Ultraviolet, or Persulfate Oxidation, or Both, and Infrared Detection
$18.9
ASTM D5091-23
Published Date: 11/01/2023
Standard Guide for Water Analysis for Electrodialysis/Electrodialysis Reversal Applications
$16.5
ASTM D4993-08(2014)
Published Date: 01/01/2014
Standard Practice for Calculation and Adjustment of Silica (SiO2) Scaling for Reverse Osmosis (Withdrawn 2023)
$18

Best-Selling Products