Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$25.8
Need Help?

1.1 This test method covers the static determination of turbidity in water. Static refers to a sample that is removed from its source and tested in an isolated instrument. (See Section 4.)

1.2 This test method is applicable to the measurement of turbidities greater than 1.0 turbidity unit (TU). The upper end of the measurement range was left undefined because different technologies described in this test method can cover very different ranges. The round robin study covered the range of 0-4000 turbidity units because instrument verification in this range can typically be covered by standards that can be consistently reproduced.

1.3 Many of the turbidity units and instrument designs covered in this test method are numerically equivalent in calibration when a common calibration standard is applied across those designs listed in Table 1. Measurement of a common calibration standard of a defined value will also produce equivalent results across these technologies.

1.3.1 In this test method calibration standards are often defined in NTU values, but the other assigned turbidity units, such as those in Table 1 are equivalent. For example, a 1 NTU formazin standard is also a 1 FNU, a 1 FAU, a 1 BU, and so forth.

1.4 This test method does not purport to cover all available technologies for high-level turbidity measurement.

1.5 This test method was tested on different natural waters and wastewater, and with standards that will serve as surrogates to samples. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

1.6 Depending on the constituents within a high-level sample, the proposed sample preparation and measurement methods may or may not be applicable. Those samples with the highest particle densities typically prove to be the most difficult to measure. In these cases, and alternative measurement method such as the process monitoring method can be considered.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this procedure.

TABLE 1 Summary of Known Instrument Designs, Applications, Ranges, and Reporting Units

Design and
Reporting Unit
Prominent ApplicationKey Design FeaturesTypical
Instrument Range
Suggested
Application Ranges
Nephelometric non-ratio (NTU)White light turbidimeters. Comply with USEPA Method 180.1 for low level turbidity monitoring.Detector centered at 90° relative to the incident light beam. Uses a white light spectral source.0.0-400.0-40 Regulatory
Ratio White Light turbidimeters (NTRU)Complies with ISWTR regulations and Standard Method 2130B. Can be used for both low and high level measurement.Used a white light spectral source. Primary detector centered at 90°. Other detectors located at other angles. An instrument algorithm uses a combination of detector readings to generate the turbidity reading.0-10 0000-40 Regulatory
0-10 000 other
Nephelometric, near-IR turbidimeters, non-ratiometric (FNU)Complies with ISO 7027. The wavelength is less susceptible to color interferences. Applicable for samples with color and good for low level monitoring.Detector centered at 90° relative to the incident light beam. Uses a near-IR (780-900 nm) monochromatic light source.0-10000-40 Regulatory (non-US)
0-1000 other
Nephelometric near-IR turbidimeters, ratio metric (FNRU)Complies with ISO 7027. Applicable for samples with high levels of color and for monitoring to high turbidity levels.Uses a near-IR monochromatic light source (780-900 nm). Primary detector centered at 90°. Other detectors located at other angles. An instrument algorithm uses a combination of detector readings to generate the turbidity reading.0-10 0000-40 Regulatory
0-10 000 other
Surface Scatter Turbidimeters (NTU)Turbidity is determined through light scatter from or near the surface of a sample.Detector centered at 90° relative to the incident light beam. Uses a white light spectral source.10-10 00010-10 000
Formazin Back Scatter (FBU)Not applicable for regulatory purposes. Best applied to high turbidity samples. Backscatter is common with but not all only probe technology and is best applied in higher turbidity samples.Uses a near-IR monochromatic light source in the 780-900 nm range. Detector geometry is between 90° and 180° relative to the incident light beam.100-10 000+ 100-10 000
Backscatter Unit (BU)Not applicable for regulatory purposes. Best applied for samples with high level turbidity.Uses a white light spectral source (400-680 nm range). Detector geometry is between 90° and 180° relative to the incident light beam.10-10 000+100-10 000+
Formazin attenuation unit (FAU)May be applicable for some regulatory purposes. This is commonly applied with spectrophotometers. Best applied for samples with high level turbidity.Detector is geometrically centered at 0° relative to incident beam (attenuation). Wavelength is 780-900 nm.20-100020-1000 Regulatory
Light attenuation unit (AU)Not applicable for some regulatory purposes. This is commonly applied with spectrophotometers.Detector is geometrically centered at 0° relative to incident beam (attenuation). Wavelength is 400-680 nm.20-100020-1000
Nephelometric Turbidity Multibeam Unit (NTMU)Is applicable to EPA regulatory method GLI Method 2. Applicable to drinking water and wastewater monitoring applications.Detectors are geometrically centered at 0° and 90°. An instrument algorithm uses a combination of detector readings, which may differ for turbidities varying magnitude.0.02-40000-40 Regulatory
0-4000 other

File Size : 1 file , 830 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 21
Published : 06/01/2012
Redline File Size : 2 files , 2 MB

History

ASTM D7315-17(2023)
Published Date: 11/01/2023
Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode
$27
ASTM D7315-17
Published Date: 07/01/2017
Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode
$32.4
ASTM D7315-12
Published Date: 06/01/2012
Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode
$25.8
ASTM D7315-07a
Published Date: 08/01/2007
Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode
$25.8
ASTM D7315-07
Published Date: 04/15/2007
Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode
$24.9

Related products

ASTM D4841-88(2018)
Published Date: 10/15/2018
Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents
$15.6
ASTM D6502-10(2022)
Published Date: 11/01/2022
Standard Test Method for Measurement of On-line Integrated Samples of Low Level Suspended Solids and Ionic Solids in Process Water by X-Ray Fluorescence (XRF)
$17.1
ASTM D3223-17
Published Date: 06/01/2017
Standard Test Method for Total Mercury in Water
$14.4

Best-Selling Products

EIA/IS 30A
Published Date: 09/01/1987
Resistors, Rectangular Surface Mount Thick Film
EIA/IS 43AA
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communication - Detail Specification for Type 1, Outdoor Cable
EIA/IS 43AC
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 1, Riser Cable
EIA/IS 43AD
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 1, Plenum Cable
EIA/IS 43AE
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 2, Non-Plenum Cable
EIA/IS 43AF
Published Date: 09/01/1988
Cable LAN Twisted Pair Data Communications - Detail Specification for Type 2, Plenum Cable