Description:

Standard Practice for Determination of Nonylphenol Polyethoxylates (NPnEO, 3 <= n <= 18) and Octylphenol Polyethoxylates (OPnEO, 2 <= n <= 12) in Water by Single Reaction Monitoring (SRM) Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$19.5
Need Help?

1.1 This procedure covers the determination of nonylphenol polyethoxylates (NPnEO, 3 n 18) and octylphenol polyethoxylates (OPnEO, 2 n 12) in water by Single Reaction Monitoring (SRM) Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS) using direct injection liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS) detection. This is a screening Practice with qualified quantitative data to check for the presence of longer chain ethoxylates in a water sample.

1.1.1 All data are qualified because neat standards of each alkylphenol ethoxylate (APEO) are not available and the synthesis and characterization of these neat standards would be very expensive. The Igepal® Brand standards, which contain a mixture of various chain lengths of the alkylphenol ethoxylates (APEOs), were used. The mixture was characterized in-house assuming the instrument response at an optimum electrospray ionization cone and collision voltage for each APEO was the same. This assumption, which may not be accurate, is used to determine qualified amounts of each ethoxylate in the standards. The n-Nonylphenol diethoxylate (n- NP2EO) surrogate was available as a neat characterized standard, therefore, this concentration and recovery data was not estimated. APEOs are not regulated by the EPA, but nonylphenol, a breakdown product of NPnEOs, is regulated for fresh and saltwater dischargers. A request by a sewage treatment plant (STP) was made to make this Practice available through ASTM in order to screen for the influent or effluent from sources of APEOs coming into the STP. The interest lies in stopping the source of the longer chain APEOs from entering the STP in order to meet effluent guidelines. Based upon the above, this is a Practice rather than a Standard Method. A comparison between samples is possible using this Practice to determine which has a higher concentration of APEOs.

1.2 Units - The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 The estimated screening range shown in Table 1 was calculated from the concentration of the Level 1 and 7 calibration standards shown in Table 4. These numbers are qualified, as explained in Section 1, and must be reported as such. Figs. 1-5 show the SRM chromatograms of each analyte at the Level 1 concentration with the signal to noise (S/N) ratio. This is a screening Practice and method detection limits are not given. The S/N ratio for each analyte at the Level 1 concentration must be at least 5:1 for adequate sensitivity. If the instrument can not meet the criteria, the screening limit must be raised to an acceptable level.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

TABLE 1 Estimated Screening Range

AnalyteEstimated Screening
Range (μg/L)
Nonylphenol
triethoxylate (NP3EO)
0.73-11.6
Nonylphenol
tetraethoxylate (NP4EO)
1.1-18.3
Nonylphenol
pentaethoxylate (NP5EO)
1.4-22.1
Nonylphenol
hexaethoxylate (NP6EO)
1.8-28.2
Nonylphenol
heptaethoxylate (NP7EO)
1.9-30.1
Nonylphenol
octaethoxylate (NP8EO)
1.8-29.2
Nonylphenol
nonaethoxylate (NP9EO)
1.6-26.3
Nonylphenol
decaethoxylate (NP10EO)
1.5-24.1
Nonylphenol
undecaethoxylate (NP11EO)
1.3-21.3
Nonylphenol
dodecaethoxylate (NP12EO)
1.0-15.7
Nonylphenol
tridecaethoxylate (NP13EO)
0.64-10.3
Nonylphenol
tetradecaethoxylate (NP14EO)
0.41-6.5
Nonylphenol
pendecaethoxylate (NP15EO)
0.21-3.4
Nonylphenol
hexadecaethoxylate (NP16EO)
0.11-1.7
Nonylphenol
heptadecaethoxylate (NP17EO)
0.05-0.80
Nonylphenol
octodecaethoxylate (NP18EO)
0.023-0.4
Total NPnEO16-250
Octylphenol
diethoxylate (OP2EO)
0.14-2.3
Octylphenol
triethoxylate (OP3EO)
1.4-22.2
Octylphenol
tetraethoxylate (OP4EO)
2.2-35.2
Octylphenol
pentaethoxylate (OP5EO)
2.9-45.8
Octylphenol
hexaethoxylate (OP6EO)
2.6-41.9
Octylphenol
heptaethoxylate (OP7EO)
2.5-40.4
Octylphenol
octaethoxylate (OP8EO)
1.8-28.8
Octylphenol
nonaethoxylate (OP9EO)
1.1-17.6
Octylphenol
decaethoxylate (OP10EO)
0.62-9.9
Octylphenol
undecaethoxylate (OP11EO)
0.26-4.2
Octylphenol
dodecaethoxylate (OP12EO)
0.11-1.8
Total OPnEO16-250
n-Nonylphenol
diethoxylate (n-NP2EO)
15.6-250 (Not Estimated)


FIG. 1 SRM Chromatograms NP3EO-NP8EO


FIG. 2 SRM Chromatograms NP9EO-NP14EO


FIG. 3 SRM Chromatograms NP15EO-NP18EO and n-NP2EO


FIG. 4 SRM Chromatograms OP2EO-OP7EO


FIG. 5 SRM Chromatograms OP8EO-OP12EO


File Size : 1 file , 740 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 12
Published : 06/15/2011

History

ASTM D7742-17(2024)
Published Date: 04/01/2024
Standard Practice for Determination of Nonylphenol Polyethoxylates (NPnEO, 3 ≤ n ≤ 18) and Octylphenol Polyethoxylates (OPnEO, 2 ≤ n ≤ 12) in Water by Single Reaction Monitoring (SRM) Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)
$20.7
ASTM D7742-17
Published Date: 12/15/2017
Standard Practice for Determination of Nonylphenol Polyethoxylates (NPnEO, 3 ≤ n ≤ 18) and Octylphenol Polyethoxylates (OPnEO, 2 ≤ n ≤ 12) in Water by Single Reaction Monitoring (SRM) Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)
$24.9
ASTM D7742-11
Published Date: 06/15/2011
Standard Practice for Determination of Nonylphenol Polyethoxylates (NPnEO, 3 <= n <= 18) and Octylphenol Polyethoxylates (OPnEO, 2 <= n <= 12) in Water by Single Reaction Monitoring (SRM) Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)
$19.5

Related products

ASTM D2035-19
Published Date: 03/01/2019
Standard Practice for Coagulation-Flocculation Jar Test of Water
$12.6
ASTM D2687-95(2024)
Published Date: 04/01/2024
Standard Practices for Sampling Particulate Ion-Exchange Materials
$18.9
ASTM D2330-20
Published Date: 01/01/2020
Standard Test Method for Methylene Blue Active Substances
$15
ASTM D5074-90(2022)
Published Date: 05/01/2022
Standard Practice for Preparation of Natural-Matrix Sediment Reference Samples for Major and Trace Inorganic Constituents Analysis by Partial Extraction Procedures
$14.4

Best-Selling Products

INFOCOMM 1M
Published Date: 11/08/2009
Audio Coverage Uniformity in Enclosed Listener Areas
INFOCOMM ACU DESIGN GUIDE
Published Date: 06/01/2011
Design Guidelines for ACU
$10.5
INFOCOMM ACU FIELD GUIDE
Published Date: 06/01/2011
ACU Field Guide
$10.5
INFOCOMM AV IMPLEMENTATION HANDBOOK
Published Date: 07/31/2012
Standard Guide for Audiovisual Systems Design and Coordination Processes
$10.5
INFOCOMM AVSEM HDBK
Published Date: 01/20/2014
AUDIOVISUAL SYSTEMS ENERGY MANAGEMENT HANDBOOK
$10.5