ASTM D93-19 PDF

ASTM D93-19 PDF

Name:
ASTM D93-19 PDF

Published Date:
11/01/2019

Status:
Active

Description:

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$22.8
Need Help?

1.1 These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 °C to 370 °C by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 °C to 190 °C by an automated Pensky-Martens closed cup apparatus.

Note 1: Flash point determinations above 250 °C can be performed, however, the precision has not been determined above this temperature. For residual fuels, precision has not been determined for flash points above 100 °C. The precision of in-use lubricating oils has not been determined. Some specifications state a D93 minimum flash point below 40 °C, however, the precision has not been determined below this temperature.

1.2 Procedure A is applicable to distillate fuels (diesel, biodiesel blends, kerosine, heating oil, turbine fuels), new and in-use lubricating oils, and other homogeneous petroleum liquids not included in the scope of Procedure B or Procedure C.

1.3 Procedure B is applicable to residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film under test conditions, or are petroleum liquids of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of Procedure A.

1.4 Procedure C is applicable to biodiesel (B100). Since a flash point of residual alcohol in biodiesel is difficult to observe by manual flash point techniques, automated apparatus with electronic flash point detection have been found suitable.

1.5 These test methods are applicable for the detection of contamination of relatively nonvolatile or nonflammable materials with volatile or flammable materials.

1.6 The values stated in SI units are to be regarded as the standard.

1.6.1 Exception-The values given in parentheses are for information only.

Note 2: It has been common practice in flash point standards for many decades to alternately use a C-scale or an F-scale thermometer for temperature measurement. Although the scales are close in increments, they are not equivalent. Because the F-scale thermometer used in this procedure is graduated in 5 °F increments, it is not possible to read it to the 2 °C equivalent increment of 3.6 °F. Therefore, for the purposes of application of the procedure of the test method for the separate temperature scale thermometers, different increments must be used. In this test method, the following protocol has been adopted: When a temperature is intended to be a converted equivalent, it will appear in parentheses following the SI unit, for example 370 °C (698 °F). When a temperature is intended to be a rationalized unit for the alternate scale, it will appear after “or,” for example, 2 °C or 5 °F.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.4, 7.1, 9.3, 9.4, 11.1.2, 11.1.4, 11.1.8, 11.2.2, and 12.1.2.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 430 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 18
Published : 11/01/2019
Redline File Size : 2 files , 930 KB

History

ASTM D93-20
Published Date: 08/01/2020
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$16.8
ASTM D93-19
Published Date: 11/01/2019
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$22.8
ASTM D93-18
Published Date: 07/01/2018
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$22.8
ASTM D93-13e1
Published Date: 07/15/2013
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-13
Published Date: 07/15/2013
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-12
Published Date: 11/01/2012
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-11
Published Date: 10/01/2011
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-10a
Published Date: 10/01/2010
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-10
Published Date: 02/15/2010
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-09
Published Date: 12/15/2009
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-08
Published Date: 10/15/2008
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-07
Published Date: 05/01/2007
Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-02a
Published Date: 12/10/2002
Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-02
Published Date: 06/10/2002
Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester
$20.1
ASTM D93-97
Published Date: 01/01/1997
Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester
$20.7
ASTM D93-94
Published Date: 01/01/1994
Standard Test Method for Flash Point by Pensky-Martens Closed Tester
$18
ASTM D93-90e1
Published Date: 01/01/1990
Standard Test Methods for Flash Point by Pensky-Martens Closed Tester
$20.7
ASTM D93-85
Published Date: 01/01/1985
Standard Test Method for Flash Point by Pensky-Martens Closed Tester
$20.7
ASTM D93-80e1
Published Date: 01/01/1980
Standard Test Methods for Flash Point By Pensky-Martens Closed Tester
$20.1
ASTM D93-71
Published Date: 01/01/1971
Standard Method Of Test For Flash Point By Pensky-Martens Closed Tester
$17.1

Related products

ASTM D3344-90(2021)
Published Date: 01/01/2021
Standard Test Method for Total Wax Content of Corrugated Paperboard
$15
ASTM D3701-23
Published Date: 11/01/2023
Standard Test Method for Hydrogen Content of Aviation Turbine Fuels by Low Resolution Nuclear Magnetic Resonance Spectrometry
$16.5
ASTM D482-19
Published Date: 11/01/2019
Standard Test Method for Ash from Petroleum Products
$13.8
ASTM D2163-23e1
Published Date: 03/01/2023
Standard Test Method for Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane/Propene Mixtures by Gas Chromatography
$18.9

Best-Selling Products

BRE AP100
Published Date: 01/01/1995
Pfa concrete; Set of four reports (BR294 to BR297)
$19.5
BRE AP135
Published Date: 01/01/2000
Value management
$15.9
BRE AP138
Published Date: 01/01/2000
BR358 Quiet homes & BR406 Specifying dwellings with enhanced sound insulation
$17.1
BRE AP139
Published Date: 01/01/2000
Domestic energy fact file; Set of four reports
$41.4
BRE AP146
Published Date: 01/01/2002
Managing sustainable construction; Profiting from sustainability
$9.3
BRE AP147
Published Date: 01/01/2002
Thaumasite in cementitous materials; Proceedings of the first international conference BRE 19-21 June 2002
$87.3