1.1 This practice covers the procedures for preparation, testing and using the acidic aqueous ferrous ammonium sulfate solution dosimetry system to measure absorbed dose to water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. The system will be referred to as the Fricke system. It is classified as a reference-standard dosimetry system (see ISO/ASTM 51261).

1.2 The practice describes the spectrophotometric analysis procedures for the Fricke dosimeter.

1.3 This practice applies only to gamma rays, x-rays (bremsstrahlung), and high-energy electrons.

1.4 This practice applies provided the following are satisfied:

1.4.1 The absorbed dose range shall be from 20 to 400 Gy (1.

1.4.2 The absorbed-dose rate does not exceed 10 6 Gys1 (2).

1.4.3 For radioisotope gamma-ray sources, the initial photon energy is greater than 0.6 MeV. For x-rays (bremsstrahlung), the initial energy of the electrons used to produce the photons is equal to or greater than 2 MeV. For electron beams, the initial electron energy is greater than 8 MeV (see ICRU Reports 34 and 35).

Note 1 - The lower energy limits given are appropriate for a cylindrical dosimeter ampoule of 12-mm outside diameter. Corrections for dose gradients across an ampoule of that diameter or less are not required.

1.4.4 The irradiation temperature of the dosimeter should be within the range of 10 to 60°C.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 130 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 8
Published : 01/01/2004

History

ASTM E1026-13
Published Date: 01/01/2013
Standard Practice for Using the Fricke Dosimetry System
$17.4
ASTM E1026-04e1
Published Date: 01/01/2004
Standard Practice for Using the Fricke Reference-Standard Dosimetry System
$17.4
ASTM E1026-04
Published Date: 01/01/2004
Standard Practice for Using the Fricke Reference Standard Dosimetry System
$17.4
ASTM E1026-03
Published Date: 07/10/2003
Standard Practice for Using the Fricke Reference Standard Dosimetry System
$17.4
ASTM E1026-95
Published Date: 01/01/1995
Standard Practice for Using the Fricke Reference Standard Dosimetry System
$17.4

Related products

ASTM E1278-88(1996)e1
Published Date: 01/01/1996
Standard Guide for Radioactive Pathway Methodology for Release of Sites Following Decommissioning (Withdrawn 2005)
$17.4
ASTM E1084-86(2023)
Published Date: 05/01/2023
Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight
$17.1
ASTM E1540-98e1
Published Date: 05/01/1998
Standard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2002)
$17.4
ASTM E1175-87(2022)
Published Date: 10/01/2022
Standard Test Method for Determining Solar or Photopic Reflectance, Transmittance, and Absorptance of Materials Using a Large Diameter Integrating Sphere
$15

Best-Selling Products

Finite Element Analysis of Elastomers
Published Date: 01/01/1999
$39.3