1.1''This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 ''m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques.

1.2''This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing.

1.3''The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice.

1.4''This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested, or for which the susceptibility to damage is unknown, is not recommended. In general, metals, metal plating, and oxide coatings will not be damaged. Application to painted, vapor deposited, and optical coatings should be evaluated before implementing this test.

1.5''This practice provides three methods to evaluate tape lift tests, as follows:

Practice

Sections

''

''

A'''This method uses light transmitted through the tape and tape adhesive to detect particles that adhere to it.

4 to 6

''

B'''This method uses light transmitted through the tape adhesive after bonding to a base microscope slide, dissolving the tape backing, and a cover slide. The particles are embedded in the adhesive, and air bubbles are eliminated with acrylic mounting media.

7 to 9

''

C'''This method uses light reflected off the tape adhesive to detect particles that adhere to it.

10 to 12

1.6''Units'''The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.

1.7''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 86 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 09/01/2021
Redline File Size : 2 files , 180 KB

History

ASTM E1216-21
Published Date: 09/01/2021
Standard Practice for Sampling for Particulate Contamination by Tape Lift
$16.2
ASTM E1216-11
Published Date: 09/01/2011
Standard Practice for Sampling for Particulate Contamination by Tape Lift
$17.4
ASTM E1216-06
Published Date: 04/01/2006
Standard Practice for Sampling for Particulate Contamination by Tape Lift
$17.4
ASTM E1216-99(2005)
Published Date: 04/01/2005
Standard Practice for Sampling for Particulate Contamination by Tape Lift
$17.4
ASTM E1216-99
Published Date: 10/10/1999
Standard Practice for Sampling for Particulate Contamination by Tape Lift
$17.4

Related products

ASTM F1105-09(2020)
Published Date: 11/01/2020
Standard Practice for Preparing Aircraft Cleaning Compounds, Liquid-Type, Temperature-Sensitive, or Solvent-Based, for Storage Stability Testing
$13.8
ASTM E459-22
Published Date: 04/01/2022
Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter
$18.9
ASTM D6507-19
Published Date: 10/15/2019
Standard Practice for Fiber Reinforcement Orientation Codes for Composite Materials
$15
ASTM F326-23
Published Date: 01/01/2023
Standard Test Method for Electronic Measurement for Hydrogen Embrittlement From Cadmium-Electroplating Processes
$17.1

Best-Selling Products

NEMA/MITA CSP 2-2021
Published Date: 2021
Lifecycle Best Practices Framework for Medical Imaging Devices
$14.7
NEMA/MITA DD P1-2019
Published Date: 08/01/2019
White Paper on Understanding the Limited Usefulness of Detector Dose Measurements in Modern Medical X-ray Imaging Equipment
$24.6
NEMA/MITA RMD P1-2019
Published Date: 01/30/2019
White Paper on Considerations for Remanufacturing of Medical Imaging Devices
$14.7
NEMA/MITA RSSTCD 1-2019
Published Date: 2019
White Paper on Radiation Safety Specification and Testing Comparison Document for Medical X-Ray Imaging Devices General Radiography and Fluoroscopy, and Interventional Fluoroscopy
$28.8
NEMA/MITA RSSTCD 2-2020
Published Date: 2020
White Paper on 21 CFR Subchapter J to IEC Comparison Table for Medical X-Ray Imaging Devices Mammography
$30
NEMA/MITA SAC 1-2020
Published Date: 2020
White Paper on Understanding Accountability in Medical Device Servicing
$14.7