ASTM E1249-15(2021) PDF

ASTM E1249-15(2021) PDF

Name:
ASTM E1249-15(2021) PDF

Published Date:
02/01/2021

Status:
Active

Description:

Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.4
Need Help?

1.1''This practice covers recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source. Co-60 sources are commonly used for the absorbed dose testing of silicon electronic devices.

Note 1:''This absorbed-dose testing is sometimes called '''total dose testing''' to distinguish it from '''dose rate testing.'''

Note 2:''The effects of ionizing radiation on some types of electronic devices may depend on both the absorbed dose and the absorbed dose rate; that is, the effects may be different if the device is irradiated to the same absorbed-dose level at different absorbed-dose rates. Absorbed-dose rate effects are not covered in this practice but should be considered in radiation hardness testing.

1.2''The principal potential error for the measurement of absorbed dose in electronic devices arises from non-equilibrium energy deposition effects in the vicinity of material interfaces.

1.3''Information is given about absorbed-dose enhancement effects in the vicinity of material interfaces. The sensitivity of such effects to low energy components in the Co-60 photon energy spectrum is emphasized.

1.4''A brief description is given of typical Co-60 sources with special emphasis on the presence of low energy components in the photon energy spectrum output from such sources.

1.5''Procedures are given for minimizing the low energy components of the photon energy spectrum from Co-60 sources, using filtration. The use of a filter box to achieve such filtration is recommended.

1.6''Information is given on absorbed-dose enhancement effects that are dependent on the device orientation with respect to the Co-60 source.

1.7''The use of spectrum filtration and appropriate device orientation provides a radiation environment whereby the absorbed dose in the sensitive region of an electronic device can be calculated within defined error limits without detailed knowledge of either the device structure or of the photon energy spectrum of the source, and hence, without knowing the details of the absorbed-dose enhancement effects.

1.8''The recommendations of this practice are primarily applicable to piece-part testing of electronic devices. Electronic circuit board and electronic system testing may introduce problems that are not adequately treated by the methods recommended here.

1.9''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 500 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 17
Published : 02/01/2021

History

ASTM E1249-15(2021)
Published Date: 02/01/2021
Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources
$17.4
ASTM E1249-10
Published Date: 12/01/2010
Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources
$19.5
ASTM E1249-00(2005)
Published Date: 06/01/2005
Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources
$19.5
ASTM E1249-00
Published Date: 06/10/2000
Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources
$19.5

Related products

ASTM E782-95(2022)
Published Date: 09/30/2022
Standard Practice for Exposure of Cover Materials for Solar Collectors to Natural Weathering Under Conditions Simulating Operational Mode
$15
ASTM E973-16(2020)
Published Date: 06/01/2020
Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell
$15
ASTM E1956-98
Published Date: 06/10/1998
Standard Practice for Use of Thermoluminescence-Dosimetry (TLD) Systems for Radiation Processing (Withdrawn 2002)
$17.4
ASTM E1538-99e1
Published Date: 06/10/1999
Standard Practice for Use of the Ethanol-Chlorobenzene Dosimetry System (Withdrawn 2002)
$17.4

Best-Selling Products

AIST/ISS DIR-20
Published Date: 01/01/2020
2020 Directory Iron and Steel Plants
$56.7
AIST/ISS PB-084
Published Date: 01/01/2002
Rolls for the Metalworking Industries
$52.5
AIST/ISS PB-099
Published Date: 01/01/2004
Continuous Casting, Volume 10: Tundish Operations
$29.4
AIST/ISS PB-126
Published Date: 01/01/2003
Austenite Formation and Decomposition
$42
AIST/ISS PB-127
Published Date: 01/01/2003
Modeling, Control, and Optimization in Ferrous and Non-Ferrous Industry
$51.9
AIST/ISS PB-210
Published Date: 01/01/2010
Bar Steels: Steel Products Manual
$31.5