ASTM E1290-07e1 PDF

ASTM E1290-07e1 PDF

Name:
ASTM E1290-07e1 PDF

Published Date:
07/15/2007

Status:
Active

Description:

Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$19.5
Need Help?
1.1 This test method covers the determination of critical crack-tip opening displacement (CTOD) values at one or more of several crack extension events. These CTOD values can be used as measures of fracture toughness for metallic materials, and are especially appropriate to materials that exhibit a change from ductile to brittle behavior with decreasing temperature. This test method applies specifically to notched specimens sharpened by fatigue cracking. The recommended specimens are three-point bend [SE(B)] compact [C(T)], or arc-shaped bend [A(B)] specimens. The loading rate is slow and influences of environment (other than temperature) are not covered. The specimens are tested under crosshead or clip gage displacement controlled loading.

1.1.1 The recommended specimen thickness, B, for the SE(B) and C(T) specimens is that of the material in thicknesses intended for an application. For the A(B) specimen, the recommended depth, W, is the wall thickness of the tube or pipe from which the specimen is obtained. Superficial surface machining may be used when desired.

1.1.2 For the recommended three-point bend specimens [SE(B)], width, W, is either equal to, or twice, the specimen thickness, B, depending upon the application of the test. (See for applications of the recommended specimens.) For SE(B) specimens the recommended initial normalized crack size is 0.45 a o/W 0.70. The span-to-width ratio (S/W) is specified as 4.

1.1.3 For the recommended compact specimen [C(T)] the initial normalized crack size is 0.45 a o/W 0.70. The half-height-to-width ratio (H/W) equals 0.6 and the width to thickness ratio W/ B is specified to be 2.

1.1.4 For the recommended arc-shaped bend [A(B)] specimen, B is one-half the specimen depth, W. The initial normalized crack size is 0.45 a o/W 0.70. The span to width ratio, S/W, may be either 3 or 4 depending on the ratio of the inner to outer tube radius. For an inner radius, r1, to an outer radius, r2, ratio of 0.6 to 1.0, a span to width ratio, S/W, of 4 may be used. For r 1/r2 ratios from 0.4 to 0.6, an S/W of 3 may be used.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
File Size : 1 file , 220 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 13
Published : 07/15/2007
Redline File Size : 2 files , 480 KB

History

ASTM E1290-08e1
Published Date: 04/01/2008
Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement (Withdrawn 2013)
$20.1
ASTM E1290-08
Published Date: 04/01/2008
Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement
$19.5
ASTM E1290-07e1
Published Date: 07/15/2007
Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement
$19.5
ASTM E1290-07
Published Date: 07/15/2007
Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement
$19.5
ASTM E1290-02e1
Published Date: 12/10/2002
Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement
$19.5
ASTM E1290-02
Published Date: 12/10/2002
Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement
$19.5
ASTM E1290-99
Published Date: 06/10/1999
Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement
$19.5

Related products

ASTM E9-19
Published Date: 04/15/2019
Standard Test Methods of Compression Testing of Metallic Materials at Room Temperature
$15.6
ASTM E45-18a(2023)
Published Date: 11/01/2023
Standard Test Methods for Determining the Inclusion Content of Steel
$20.7
ASTM E2444-11(2018)
Published Date: 05/01/2018
Standard Terminology Relating to Measurements Taken on Thin, Reflecting Films
$12.6
ASTM E1012-19
Published Date: 12/15/2019
Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application
$17.4

Best-Selling Products

ISUZU ADHES/SEAL RENEWAL
Published Date: 01/01/2000
ISUZU ADHESIVES/SEALERS RENEWAL
ISUZU COATINGS RENEWAL
Published Date: 01/01/2000
ISUZU COATINGS, PLASTICS & RUBBER RENEWAL
ISUZU COATINGS U02/06
Published Date: 06/01/2002
ISUZU COATINGS UPDATE 02/06
ISUZU COATINGS U03/04
Published Date: 04/01/2003
ISUZU COATINGS UPDATE 03/04
ISUZU FUELS/LUBES RENEWAL
Published Date: 01/01/2000
ISUZU FUELS/LUBES & COOLANT RENEWAL
ISUZU FUELS/LUBES U01/08
Published Date: 08/01/2001
ISUZU FUELS/LUBES UPDATE 01/08