1.3 Basis of Application-There are areas in this practice that may require agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract.
1.3.1 DoD contracts.
1.3.2 Personnel qualification, 5.1.1.
1.3.3 Agency qualification, 5.1.2.
1.3.4 Digitizing techniques, 5.4.5.
1.3.5 Alternate image quality indicator (IQI) types, 5.5.3.
1.3.6 Examination sequence, 6.6.
1.3.7 Non-film techniques, 6.7.
1.3.8 Radiographic quality levels, 6.9.
1.3.9 Optical density, 6.10.
1.3.10 IQI qualification exposure, 6.13.3.
1.3.11 Non-requirement for IQI, 6.18.
1.3.12 Examination coverage for welds, A2.2.2.
1.3.13 Electron beam welds, A2.3.
1.3.14 Geometric unsharpness, 6.23.
1.3.15 Responsibility for examination, 6.27.1.
1.3.16 Examination report, 6.27.2.
1.3.17 Retention of radiographs, 6.27.8.
1.3.18 Storage of radiographs, 6.27.9.
1.3.19 Reproduction of radiographs, 6.27.10 and 6.27.10.1.
1.3.20 Acceptable parts, 6.28.1.