ASTM E2121-12 PDF

ASTM E2121-12 PDF

Name:
ASTM E2121-12 PDF

Published Date:
04/15/2012

Status:
Active

Description:

Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$19.5
Need Help?

1.1 This practice describes methods for reducing radon entry into existing attached and detached residential buildings three stories or less in height. This practice is intended for use by trained, certified or licensed, or both, or otherwise qualified individuals.

1.2 These methods are based on radon mitigation techniques that have been effective in reducing radon levels in a wide range of residential buildings and soil conditions. These fan powered mitigation methods are listed in Appendix X1. More detailed information is contained in references cited throughout this practice.

1.3 This practice is intended to provide radon mitigation contractors with a uniform set of practices that will ensure a high degree of safety and the likelihood of success in retrofitting low rise residential buildings with radon mitigation systems.

1.4 The methods described in this practice apply to currently occupied or formerly occupied residential buildings, including buildings converted or being converted to residential use, as well as residential buildings changed or being changed by addition(s) or alteration(s), or both. The radon reduction activities performed on new dwellings, while under construction, before occupancy, and for up to one year after occupancy, are covered by Guide E1465.

1.5 This practice also is intended as a model set of practices, which can be adopted or modified by state and local jurisdictions, to fulfill objectives of their specific radon contractor certification or licensure programs. Radon mitigation performed in accordance with this practice is considered ordinary repair.

1.6 The methods addressed in this practice include the following categories of contractor activity: general practices, building investigation, systems design, systems installation, materials, monitors and labeling, post-mitigation testing, and documentation.

1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety hazards.


File Size : 1 file , 140 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 13
Published : 04/15/2012
Redline File Size : 2 files , 250 KB

History

ASTM E2121-21
Published Date: 10/01/2021
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$18
ASTM E2121-13
Published Date: 03/01/2013
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$21.6
ASTM E2121-12
Published Date: 04/15/2012
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$19.5
ASTM E2121-11
Published Date: 11/01/2011
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$19.5
ASTM E2121-09
Published Date: 11/01/2009
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$19.5
ASTM E2121-08
Published Date: 06/15/2008
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$19.5
ASTM E2121-03
Published Date: 02/10/2003
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$19.5
ASTM E2121-02a
Published Date: 12/10/2002
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$19.5
ASTM E2121-02
Published Date: 05/10/2002
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
$19.5

Related products

ASTM E1729-24
Published Date: 04/01/2024
Standard Practice for Field Collection of Dried Paint Samples for Subsequent Lead Determination
$18.9
ASTM E1827-22
Published Date: 10/01/2022
Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
$18.9
ASTM E2692-10(2018)
Published Date: 09/01/2018
Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products
$14.4

Best-Selling Products

ASD-STAN 2000M CD
Published Date: 10/01/1998
International Specification for Material Management Integrated Data Processing for Military Equipment
ASD-STAN CTI/79/8089
Published Date: 01/01/1979
Tool Numbering Unification in the European Aerospace Industries
ASD-STAN DOA SET
Published Date: 01/16/2019
Design Organisation Approval standards
$277.2
ASD-STAN PREN 2000
Published Date: 10/01/2003
Aerospace Series Quality Assurance EN Aerospace Products Approval of the Quality Systems of Manufacturers
$13.2
ASD-STAN PREN 2002-001
Published Date: 03/01/2019
Aerospace series Metallic materials Test methods Part 001: Tensile testing at ambient temperature
$57.9
ASD-STAN prEN 2002-003
Published Date: 06/01/1979
Test methods for metallic materials - Part 3 : Load calibration of tensile testing machines
$5.232