ASTM E2330-19 PDF

ASTM E2330-19 PDF

Name:
ASTM E2330-19 PDF

Published Date:
12/01/2019

Status:
Active

Description:

Standard Test Method for Determination of Concentrations of Elements in Glass Samples Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Forensic Comparisons

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$16.2
Need Help?

1.1 One objective of a forensic glass examination is to compare glass samples to determine if they can be discriminated using their physical, optical or chemical properties (for example, color, refractive index (RI), density, elemental composition). If the samples are distinguishable in any of these observed and measured properties, it may be concluded that they did not originate from the same source of broken glass. If the samples are indistinguishable in all of these observed and measured properties, the possibility that they originated from the same source of glass cannot be eliminated. The use of an elemental analysis method such as inductively coupled plasma mass spectrometry yields high discrimination among sources of glass. (1-16)2

1.2 This test method covers a procedure for quantitative determination of the concentrations of magnesium (Mg), aluminum (Al), iron (Fe), titanium (Ti), manganese (Mn), rubidium (Rb), strontium (Sr), zirconium (Zr), barium (Ba), lanthanum (La), cerium (Ce), neodymium (Nd), samarium (Sm), and lead (Pb) in glass samples.

1.3 This procedure is applicable to irregularly shaped samples as small as 200 micrograms, for the comparison of fragments of a known source to the recovered fragments from a questioned source. These elements are present in soda lime and borosilicate glass in μg/L to % levels.

1.4 This procedure is applicable to other elements, other types of glass, and other concentration ranges with appropriate modifications of the digestion procedure (if needed for full recovery of the additional elements), calibration standards and the mass spectrometer conditions. Calcium and potassium, for example, could be added to the list of analytes in a modified analysis scheme. Alternative methods for the determination of concentrations of elements in glass are listed in the references.

1.5 For any given glass, approximately 40 elements are likely to be present at detectable concentrations using this procedure with minor modifications. The element set stated here is an example of some of these elements that can be detected in glass and used for forensic comparisons.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard cannot replace knowledge, skills, or abilities acquired through education, training, and experience and is to be used in conjunction with professional judgment by individuals with such discipline-specific knowledge, skills, and abilities.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 88 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 7
Published : 12/01/2019
Redline File Size : 2 files , 200 KB

History

ASTM E2330-19
Published Date: 12/01/2019
Standard Test Method for Determination of Concentrations of Elements in Glass Samples Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Forensic Comparisons
$16.2
ASTM E2330-12
Published Date: 06/15/2012
Standard Test Method for Determination of Concentrations of Elements in Glass Samples Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Forensic Comparisons
$18
ASTM E2330-04
Published Date: 08/01/2004
Standard Test Method for Determination of Trace Elements in Glass Samples Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
$17.4

Related products

ASTM E674-12(2021)
Published Date: 09/01/2021
Standard Specification for Industrial Perforated Plate and Screens (Round Opening Series)
$18
ASTM E1919-09
Published Date: 11/01/2009
Standard Guide for Worldwide Published Standards Relating to Particle and Spray Characterization (Withdrawn 2014)
$17.4
ASTM E1231-24
Published Date: 05/15/2024
Standard Practice for Calculation of Hazard Potential Figures of Merit for Thermally Unstable Materials
$18.9
ASTM E1860-23
Published Date: 08/01/2023
Standard Test Method for Elapsed Time Calibration of Thermal Analyzers
$15

Best-Selling Products

Operation of Small Wastewater Systems
Published Date: 08/01/1997
$11.7
Small Water Systems Operation & Maintenance
Published Date: 02/01/1999
$7.8
Water Treatment Plant Operation, Volume 1
Published Date: 07/01/1999
$11.7