Description:

Standard Practice for Setting an Upper Confidence Bound for a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-Conformities, Using Attribute Data, When There is a Zero Response in the Sample

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.1
Need Help?
1.1 This practice presents methodology for the setting of an upper confidence bound regarding a unknown fraction or quantity non-conforming, or a rate of occurrence for nonconformities, in cases where the method of attributes is used and there is a zero response in a sample. Three cases are considered.
1.1.1 The sample is selected from a process or a very large population of discrete items, and the number of non-conforming items in the sample is zero.
1.1.2 A sample of items is selected at random from a finite lot of discrete items, and the number of non-conforming items in the sample is zero.
1.1.3 The sample is a portion of a continuum (time, space, volume, area, etc.) and the number of non-conformities in the sample is zero.
1.2 Allowance is made for misclassification error in this practice, but only when misclassification rates are well understood or known and can be approximated numerically.
1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

File Size : 1 file , 510 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 10
Published : 01/01/2023

History

ASTM E2334-09(2023)
Published Date: 01/01/2023
Standard Practice for Setting an Upper Confidence Bound for a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-Conformities, Using Attribute Data, When There is a Zero Response in the Sample
$17.1
ASTM E2334-09(2018)
Published Date: 09/01/2018
Standard Practice for Setting an Upper Confidence Bound for a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-Conformities, Using Attribute Data, When There is a Zero Response in the Sample
$20.4
ASTM E2334-09(2013)e1
Published Date: 04/01/2013
Standard Practice for Setting an Upper Confidence Bound For a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-conformities, Using Attribute Data, When There is a Zero Response in the Sample
$17.4
ASTM E2334-09(2013)
Published Date: 04/01/2013
Standard Practice for Setting an Upper Confidence Bound For a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-conformities, Using Attribute Data, When There is a Zero Response in the Sample
$17.4
ASTM E2334-09
Published Date: 11/01/2009
Standard Practice for Setting an Upper Confidence Bound For a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-conformities, Using Attribute Data, When There is a Zero Response in the Sample
$17.4
ASTM E2334-08
Published Date: 10/15/2008
Standard Practice for Setting an Upper Confidence Bound For a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-conformities, Using Attribute Data, When There is a Zero Response in the Sample
$17.4
ASTM E2334-03e1
Published Date: 10/01/2003
Standard Practice for Setting an Upper Confidence Bound For a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-conformities, Using Attribute Data, When There is a Zero Response in the Sample
$17.4
ASTM E2334-03
Published Date: 10/01/2003
Standard Practice for Setting an Upper Confidence Bound For a Fraction or Number of Non-Conforming items, or a Rate of Occurrence for Non-conformities, Using Attribute Data, When There is a Zero Response in the Sample
$17.4

Related products

ASTM E1239-04(2010)
Published Date: 03/01/2010
Standard Practice for Description of Reservation/Registration-Admission, Discharge, Transfer (R-ADT) Systems for Electronic Health Record (EHR) Systems (Withdrawn 2017)
$19.5
ASTM E2553-07(2013)
Published Date: 03/01/2013
Standard Guide for Implementation of a Voluntary Universal Healthcare Identification System (Withdrawn 2022)
$21.6
ASTM E1384-07(2013)
Published Date: 04/15/2013
Standard Practice for Content and Structure of the Electronic Health Record (EHR) (Withdrawn 2017)
$36
ASTM E141-10(2023)
Published Date: 11/01/2023
Standard Practice for Acceptance of Evidence Based on the Results of Probability Sampling
$18.9

Best-Selling Products

Vitamins and Minerals Handbook
Published Date: 04/01/2001
$3.9