ASTM E668-13 PDF

ASTM E668-13 PDF

Name:
ASTM E668-13 PDF

Published Date:
01/01/2013

Status:
Active

Description:

Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-e668-13_1851349

Choose Document Language:
20.10 €
Need Help?

1.1 This practice covers procedures for the use of thermoluminescence dosimeters (TLDs) to determine the absorbed dose in a material irradiated by ionizing radiation. Although some elements of the procedures have broader application, the specific area of concern is radiation-hardness testing of electronic devices. This practice is applicable to the measurement of absorbed dose in materials irradiated by gamma rays, X rays, and electrons of energies from 12 to 60 MeV. Specific energy limits are covered in appropriate sections describing specific applications of the procedures. The range of absorbed dose covered is approximately from 10???2 to 104 Gy (1 to 106 rad), and the range of absorbed dose rates is approximately from 10???2 to 1010 Gy/s (1 to 1012 rad/s). Absorbed dose and absorbed dose-rate measurements in materials subjected to neutron irradiation are not covered in this practice. (See Practice E2450 for guidance in mixed fields.) Further, the portion of these procedures that deal with electron irradiation are primarily intended for use in parts testing. Testing of devices as a part of more massive components such as electronics boards or boxes may require techniques outside the scope of this practice.

Note 1???The purpose of the upper and lower limits on the energy for electron irradiation is to approach a limiting case where dosimetry is simplified. Specifically, the dosimetry methodology specified requires that the following three limiting conditions be approached: (a) energy loss of the primary electrons is small, (b) secondary electrons are largely stopped within the dosimeter, and (c) bremsstrahlung radiation generated by the primary electrons is largely lost.

1.2 This standard dose not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 260 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 19
Published : 01/01/2013
Redline File Size : 2 files , 510 KB

History

ASTM E668-20
Published Date: 07/01/2020
Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
16.80 €
ASTM E668-13
Published Date: 01/01/2013
Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
20.10 €
ASTM E668-10
Published Date: 06/01/2010
Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
20.10 €
ASTM E668-05
Published Date: 06/01/2005
Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
20.10 €
ASTM E668-00
Published Date: 06/10/2000
Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
19.50 €

Related products

ASTM E666-21
Published Date: 02/01/2021
Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation
15.60 €
ASTM E668-20
Published Date: 07/01/2020
Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
16.80 €
ASTM E1893-15(2021)
Published Date: 02/01/2021
Standard Guide for Selection and Use of Portable Radiological Survey Instruments for Performing In Situ Radiological Assessments to Support Unrestricted Release from Further Regulatory Controls
22.50 €
ASTM E1760-16(2024)
Published Date: 05/01/2024
Standard Guide for Unrestricted Disposition of Bulk Materials Containing Residual Amounts of Radioactivity
18.90 €

Best-Selling Products

AS/NZS 10002:2014
Published Date: 10/29/2014
Guidelines for complaint management in organizations
31.68 €
AS/NZS 1015:2011
Published Date: 10/07/2011
Records management - Physical storage
21.58 €
AS/NZS 1020:1995
Published Date: 03/05/1995
The control of undesirable static electricity
36.63 €
AS/NZS 1020:2023
Published Date: 06/02/2023
The control of static electricity in non-hazardous areas
23.17 €
AS/NZS 1026:2004
Published Date: 04/29/2004
Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV
30.49 €
AS/NZS 1044:1992
Published Date: 08/17/1992
Limits and methods of measurement of radio interference characteristics of household electrical appliances, portable tools and similar electrical apparatus
33.26 €