ASTM E746-07(2014) PDF

ASTM E746-07(2014) PDF

Name:
ASTM E746-07(2014) PDF

Published Date:
07/01/2014

Status:
Active

Description:

Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18
Need Help?

1.1 This standard provides a practice whereby industrial radiographic imaging systems may be comparatively assessed using the concept of relative image quality response (RIQR). The RIQR method presented within this practice is based upon the use of equivalent penetrameter sensitivity (EPS) described within Practice E1025 and subsection 5.2 of this practice. Figure 1 illustrates a relative image quality indicator (RIQI) that has four different steel plaque thicknesses (.015, .010, .008, and .005 in.) sequentially positioned (from top to bottom) on a ³/4-in. thick steel plate. The four plaques contain a total of 14 different arrays of penetrameter-type hole sizes designed to render varied conditions of threshold visibility ranging from 1.92 % EPS (at the top) to .94 % EPS (at the bottom) when exposed to nominal 200 keV X-ray radiation. Each “EPS” array consists of 30 identical holes; thus, providing the user with a quantity of threshold sensitivity levels suitable for relative image qualitative response comparisons.

FIG. 1 Relative Image Quality Indicator


Step Identification

Shim Thickness, mm (in.)

Hole Identification

Hole Size, mm (in.)

 

 

15

0.38 ± 0.012 (0.015 ± 0.0005)

32

0.81 ± 0.025 (0.032 ± 0.001)

 

10

0.25 ± 0.012 (0.010 ± 0.0005)

31

0.79 ± 0.025 (0.031 ± 0.001)

 

 8

0.20 ± 0.012 (0.008 ± 0.0005)

28

0.71 ± 0.025 (0.028 ± 0.001)

 

 5

0.13 ± 0.012 (0.005 ± 0.0005)

25

0.64 ± 0.025 (0.025 ± 0.001)

 

 

 

23

0.58 ± 0.025 (0.023 ± 0.001)

 

 

 

20

0.50 ± 0.025 (0.020 ± 0.001)

 

Hole Spacing (horizontal): 5 ± 0.1 mm (0.2 ± 0.004 in.) Nonaccumulative

 

 

 

Row Spacing: 3 ± 0.1 mm (0.2 ± 0.004 in.)

 

 

 

Spacing between hole sets: 5 ± 0.1 mm (0.2 ± 0.004 in.)

 

 

 

All other dimensions shall be in accordance with standard engineering practice.

 

 

 

1.2 This practice is not intended to qualify the performance of a specific radiographic technique nor for assurance that a radiographic technique will detect specific discontinuities in a specimen undergoing radiographic examination. This practice is not intended to be used to classify or derive performance classification categories for radiographic imaging systems. For example, performance classifications of radiographic film systems may be found within Test Method E1815.

1.3 This practice contains an alternate provision whereby industrial radiographic imaging systems may be comparatively assessed using Lucite plastic material exposed to nominal 30 keV X-ray radiation. The RIQI for this alternate evaluation is also illustrated in Fig. 1, except the plaque and base plate materials are constructed of Lucite plastic in lieu of steel. EPS values for Lucite plastic are provided in Section 5 based upon the use of a 1³/8-in. thick Lucite base plate. For high-energy X-ray applications (4 to 25 MeV), Test Method E1735 provides a similar RIQR standard practice.

1.4 The values stated in SI are to be regarded as the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 170 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 7
Published : 07/01/2014

History

ASTM E746-23
Published Date: 12/01/2023
Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems below 4 MeV
$18.9
ASTM E746-18
Published Date: 02/01/2018
Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems
$22.5
ASTM E746-17
Published Date: 11/01/2017
Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems
$17.4
ASTM E746-07(2014)
Published Date: 07/01/2014
Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems
$18
ASTM E746-07
Published Date: 12/01/2007
Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems
$18
ASTM E746-02
Published Date: 01/10/2002
Standard Test Method for Determining Relative Image Quality Response of Industrial Radiographic Film
$18
ASTM E746-93(1998)
Published Date: 01/01/1998
Standard Test Method for Determining Relative Image Quality Response of Industrial Radiographic Film
$17.4

Related products

ASTM E1814-14(2022)
Published Date: 07/01/2022
Standard Practice for Computed Tomographic (CT) Examination of Castings
$14.4
ASTM E1419/E1419M-15a(2020)
Published Date: 06/01/2020
Standard Practice for Examination of Seamless, Gas-Filled, Pressure Vessels Using Acoustic Emission
$15
ASTM E317-21
Published Date: 06/01/2021
Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Testing Instruments and Systems without the Use of Electronic Measurement Instruments
$17.4

Best-Selling Products

CEPT T/R 34-01
Published Date: 01/01/1987
Specifications Des Equipements Radioelectriques Mobiles Maritimes
$12.6
CEPT T/SF 66 E
Published Date: 01/01/1990
Services and Facilities Aspects of Digital European Cordless Telecommunications (DECT)
$1.5