ASTM E816-05(2010) PDF

ASTM E816-05(2010) PDF

Name:
ASTM E816-05(2010) PDF

Published Date:
12/01/2010

Status:
Active

Description:

Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$20.1
Need Help?

1.1 This test method has been harmonized with, and is technically equivalent to, ISO 9059.

1.2 Two types of calibrations are covered by this test method. One is the calibration of a secondary reference pyrheliometer using an absolute cavity pyrheliometer as the primary standard pyrheliometer, and the other is the transfer of calibration from a secondary reference to one or more field pyrheliometers. This test method proscribes the calibration procedures and the calibration hierarchy, or traceability, for transfer of the calibrations.

Note 1 - It is not uncommon, and is indeed desirable, for both the reference and field pyrheliometers to be of the same manufacturer and model designation.

1.3 This test method is relevant primarily for the calibration of reference pyrheliometers with field angles of 5 to 6°, using as the primary reference instrument a self-calibrating absolute cavity pyrheliometer having field angles of about 5°. Pyrheliometers with field angles greater than 6.5° shall not be designated as reference pyrheliometers.

1.4 When this test method is used to transfer calibration to field pyrheliometers having field angles both less than 5° or greater than 6.5°, it will be necessary to employ the procedure defined by Angstrom and Rodhe.

1.5 This test method requires that the spectral response of the absolute cavity chosen as the primary standard pyrheliometer be nonselective over the range from 0.3 to 10 μm wavelength. Both reference and field pyrheliometers covered by this test method shall be nonselective over a range from 0.3 to 4 μm wavelength.

1.6 The primary and secondary reference pyrheliometers shall not be field instruments and their exposure to sunlight shall be limited to calibration or intercomparisons. These reference instruments shall be stored in an isolated cabinet or room equipped with standard laboratory temperature and humidity control.

Note 2 - At a laboratory where calibrations are performed regularly, it is advisable to maintain a group of two or three secondary reference pyrheliometers that are included in every calibration. These serve as controls to detect any instability or irregularity in the standard reference pyrheliometer.

1.7 This test method is applicable to calibration procedures using natural sunshine only.


File Size : 1 file , 240 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 11
Published : 12/01/2010

History

ASTM E816-15(2023)
Published Date: 03/15/2023
Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
$18.9
ASTM E816-05(2010)
Published Date: 12/01/2010
Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
$20.1
ASTM E816-05
Published Date: 10/01/2005
Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
$20.1
ASTM E816-95(2002)
Published Date: 04/15/1995
Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
$18
ASTM E816-95
Published Date: 01/01/1995
Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
$17.4

Related products

ASTM E133-92(2022)
Published Date: 01/01/2022
Standard Specification for Distillation Equipment
$14.4
ASTM E1154-23
Published Date: 01/01/2023
Standard Specification for Piston or Plunger Operated Volumetric Apparatus and Operator Qualification
$18.9
ASTM E1272-02(2019)
Published Date: 01/01/2019
Standard Specification for Laboratory Glass Graduated Cylinders
$12.6
ASTM E1379-90(2022)
Published Date: 08/31/2022
Standard Specification for Laboratory Glass Dewar Flask
$14.4

Best-Selling Products

BS ISO/TS 12927:1999
Published Date: 07/15/2000
Lubricants, industrial oils and related products (class L). Family M (metalworking). Guidelines for establishing specifications
$92.964
BS ISO/TS 12928:1999
Published Date: 08/15/2000
Lubricants, industrial oils and related products (class L). Family R (products for temporary protection against corrosion). Guidelines for establishing specifications
$92.964
BS ISO/TS 13399-2:2005
Published Date: 05/11/2005
Cutting tool data representation and exchange. Reference dictionary for the cutting items
$78.486
BS ISO/TS 13725:2001
Published Date: 09/24/2001
Hydraulic fluid power. Cylinders. Method for determining the buckling load
$105.156
BS ISO/TS 15768:2000
Published Date: 12/15/2000
Measurement of liquid velocity in open channels. Design, selection and use of electromagnetic current meters
$57.15
BS ISO/TS 15769:2000
Published Date: 02/15/2001
Hydrometric determination. Liquid flow in open channels and partly filled pipes. Guidelines for the application of Doppler-based flow measurements
$79.248