1.1 This test method describes the use of solid-state track recorders (SSTRs) for neutron dosimetry in light-water reactor (LWR) applications. These applications extend from low neutron fluence to high neutron fluence, including high power pressure vessel surveillance and test reactor irradiations as well as low power benchmark field measurement. (1) This test method replaces Method E 418. This test method is more detailed and special attention is given to the use of state-of-the-art manual and automated track counting methods to attain high absolute accuracies. In-situ dosimetry in actual high fluence-high temperature LWR applications is emphasized.

1.2 This test method includes SSTR analysis by both manual and automated methods. To attain a desired accuracy, the track scanning method selected places limits on the allowable track density. Typically good results are obtained in the range of 5 to 800 000 tracks/cm² and accurate results at higher track densities have been demonstrated for some cases. (2) Track density and other factors place limits on the applicability of the SSTR method at high fluences. Special care must be exerted when measuring neutron fluences (E>1MeV) above 1016 n/cm². (3)

1.3 High fluence limitations exist. These limitations are discussed in detail in Section 13 and in references (3-5).

1.4 SSTR observations provide time-integrated reaction rates. Therefore, SSTR are truly passive-fluence detectors. They provide permanent records of dosimetry experiments without the need for time-dependent corrections, such as decay factors that arise with radiometric monitors.

1.5 Since SSTR provide a spatial record of the time-integrated reaction rate at a microscopic level, they can be used for "fine-structure" measurements. For example, spatial distributions of isotopic fission rates can be obtained at very high resolution with SSTR.

1.6 This standard does not purport to address the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 290 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 16
Published : 06/01/2009
Redline File Size : 2 files , 540 KB

History

ASTM E854-19
Published Date: 11/01/2019
Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance
16.80 €
ASTM E854-14
Published Date: 07/01/2014
Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)
19.50 €
ASTM E854-03(2009)
Published Date: 06/01/2009
Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)
20.10 €
ASTM E854-03
Published Date: 02/10/2003
Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)
20.10 €
ASTM E854-98
Published Date: 01/10/1998
Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)
19.50 €

Related products

ASTM E854-19
Published Date: 11/01/2019
Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance
16.80 €
ASTM E264-19
Published Date: 04/01/2019
Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel
14.40 €
ASTM E481-23
Published Date: 06/01/2023
Standard Practice for Measuring Neutron Fluence Rates by Radioactivation of Cobalt and Silver
17.10 €
ASTM E948-16(2020)
Published Date: 06/01/2020
Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight
15.00 €

Best-Selling Products

ACID, SULFUTIC, AND OLEUM
Published Date: 01/31/1945
7.20 €
DOD DOD-1000.21-R
Published Date: 04/01/1997
PASSPORT AND PASSPORT AGENT SERVICES REGULATION
11.40 €
DOD DOD-1010.13-R
Published Date: 03/01/1992
OVERSEAS ASSIGNMENT OF SPONSORS WHO HAVE CHILDREN WITH DISABILITIES WHO ARE SPACE-REQUIRED STUDENTS IN THE DEPARTMENT OF DEFENSE DEPENDENTS SCHOOLS
11.40 €
DOD DOD-1015.8-R
Published Date: 11/01/1985
DOD CIVILIAN EMPLOYEE MORALE, WELFARE AND RECREATION (MWR) ACTIVITIES AND SUPPORTING NONAPPROPRIATED FUND INSTRUMENTALITIES (NAFIS)
10.20 €
DOD DOD-1100.18-H
Published Date: 10/01/1986
MOBILIZATION HANDBOOK FOR INSTALLATION MANPOWER PLANNERS
17.70 €
DOD DOD-1100.19-H
Published Date: 03/01/1990
WARTIME MANPOWER MOBILIZATION PLANNING GUIDANCE
15.60 €