ASTM E925-83(1994)e1 PDF

ASTM E925-83(1994)e1 PDF

Name:
ASTM E925-83(1994)e1 PDF

Published Date:
01/01/1994

Status:
Active

Description:

Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Slit Width does not Exceed 2 nm

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.4
Need Help?
1.1 This practice covers the parameters of spectrophotometric performance that are critical for testing the adequacy of instrumentation for most routine tests and methods within the wavelength range of 200 to 700 nm and the absorbance range of 0 to 2. The recommended tests provide a measurement of the important parameters controlling results in spectrophotometric methods, but it is specifically not to be inferred that all factors in instrument performance are measured.

1.2 This practice may be used as a significant test of the performance of instruments for which the spectral slit width does not exceed 2 nm and for which the manufacturer's specifications for wavelength and absorbance accuracy do not exceed the performance tolerances employed here. This practice employs an illustrative tolerance of 1 % relative for the error of the absorbance scale over the range of 0.2 to 2.0, and of 1.0 nm for the error of the wavelength scale. A suggested maximum stray radiant power ratio of 4 x 10-4 yields 1 % absorbance bias at an absorbance of 2. These tolerances are chosen to be compatible with many chemical applications while comfortably exceeding the uncertainty of the certified values for the reference materials and typical manufacturer's specifications for error in the wavelength and absorbance scales of the instrument under test. The user is encouraged to develop and use tolerance values more appropriate to the requirements of the end use application. This procedure is designed to verify quantitative performance on an ongoing basis and to compare one instrument's performance with that of other similar units. Refer to Practice E 275 to extensively evaluate the performance of an instrument

1.3 This practice should be performed on a periodic basis, the frequency of which depends on the physical environment within which the instrumentation is used. Thus, units handled roughly or used under adverse conditions (exposed to dust, chemical vapors, vibrations, or combinations thereof) should be tested more frequently than those not exposed to such conditions. This practice should also be performed after any significant repairs are made on a unit, such as those involving the optics, detector, or radiant energy source.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
File Size : 1 file , 32 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 6
Published : 01/01/1994

History

ASTM E925-09(2022)
Published Date: 11/01/2022
Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidth does not Exceed 2 nm
$17.1
ASTM E925-09(2014)
Published Date: 05/01/2014
Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidth does not Exceed 2 nm
$20.4
ASTM E925-09
Published Date: 10/01/2009
Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Slit Width does not Exceed 2 nm
$18
ASTM E925-02
Published Date: 03/10/2002
Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Slit Width does not Exceed 2 nm
$18
ASTM E925-83(1994)e1
Published Date: 01/01/1994
Standard Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Slit Width does not Exceed 2 nm
$17.4

Related products

ASTM E1162-11(2019)
Published Date: 11/01/2019
Standard Practice for Reporting Sputter Depth Profile Data in Secondary Ion Mass Spectrometry (SIMS)
$13.2
ASTM E1653-94(2021)
Published Date: 09/01/2021
Standard Guide for Specifying Dynamic Characteristics of Optical Radiation Transmitting Fiber Waveguides
$13.8
ASTM E578-07(2021)
Published Date: 04/01/2021
Standard Test Method for Linearity of Fluorescence Measuring Systems
$13.8

Best-Selling Products

IEC/TS 60034-16-2 Ed. 1.0 b:1991
Published Date: 02/15/1991
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Chapter 2: Models for power system studies
$33
IEC/TS 60034-16-3 Ed. 1.0 b:1996
Published Date: 02/14/1996
Rotating electrical machines - Part 16: Excitation systems for synchronous machines - Section 3: Dynamic performance
$43.5
IEC/TS 60034-17 Ed. 3.0 b:2002
Published Date: 03/26/2002
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$18.3
IEC/TS 60034-17 Ed. 4.0 b:2006
Published Date: 05/09/2006
Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
$47.1
IEC/TS 60034-18-32 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 32: Test procedures for form-wound windings - Electrical evaluation of insulation systems used in machines up to and including 50 MVA and 15 kV
$18.3
IEC/TS 60034-18-33 Ed. 1.0 b:1995
Published Date: 03/29/1995
Rotating electrical machines - Part 18: Functional evaluation of insulation systems - Section 33: Test procedures for form-wound windings - Multifactor functional evaluation - Endurance under combined thermal and electrical stresses of insulation systems used in machines up to and including 50 MVA a
$32.1