ASTM F1266-89(1998) PDF

ASTM F1266-89(1998) PDF

Name:
ASTM F1266-89(1998) PDF

Published Date:
01/01/1998

Status:
Active

Description:

Standard Performance Specification for Cerebral Stereotactic Instruments

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18.6
Need Help?

1.1 This specification covers stereotactic instruments used by neurosurgeons to assist in the placement of probes, such as cannulae, needles, forceps, or electrodes or to direct radiation into brain regions or anatomical targets that are not visible on the surface. The general location of these regions is determined by measurements from landmarks visualized by X ray or other means, such measurements being based on atlases derived from anatomical studies and autopsy. Because of the anatomical variability, more precise location in any single patient may be determined by physiological responses in that patient. The degree of success in stereotactic surgery depends upon the experience of the surgeon as well as the precision of the stereotactic instrument. Nevertheless, minimum standards of accuracy for stereotactic instruments that are within the range of variability of human anatomy must be maintained.

1.2 For the purpose of this specification, a stereotactic instrument is a guiding device used in human neurosurgery for the purpose of directing an instrument or treating modality to a specific point within the brain by radiographic or other visualization of landmarks.

1.3 Stereotactic instruments must be constructed to afford the surgeon reliably reproducible accuracy in placing instruments into target areas. Proper positioning of the probe is often verified by X rays to control errors in calculation and to correct deflection of the probe during insertion. Physiological parameters may be used to further define the optimal target.

1.4 At the present time, stereotactic instruments are used most frequently, but not exclusively in the following operations. The list is presented only to present examples and should not be construed to restrict advances or developments of new procedures. For some applications it is not required to hit a point in space, but to hit a volume or make a lesion within a mass. For that purpose, devices other than those covered by this specification may be employed, but should be restricted to such uses.

1.4.1 Thalamotomy for parkinsonism and other types of tremor,

1.4.2 Electrode implantation for epilepsy,

1.4.3 Needle or magnetic insertion, or both, for aneurysm thrombosis,

1.4.4 Thalamic or subthalamic operations for dystonia,

1.4.5 Thalamic or subthalamic operations for involuntary movements such as chorea or hemiballismus,

1.4.6 Ablation of deep cerebellar nuclei for spasticity,

1.4.7 Cingulotomy and thalamic or subthalamic surgery for pain,

1.4.8 Mesencephalotomy or tractotomy for pain,

1.4.9 Ablations of subcortical temporal lobe structures for treatment of epilepsy,

1.4.10 Psychosurgical procedures,

1.4.11 Implantation of depth stimulating electrodes for pain,

1.4.12 Insertion of forceps or needle for obtaining biopsy specimens,

1.4.13 Foreign body removal,

1.4.14 Implantation of radioactive material, and

1.4.15 Biopsy or treatment of tumors.

1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 55 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 6
Published : 01/01/1998

History

ASTM F1266-89(2008)
Published Date: 02/01/2008
Standard Performance Specification for Cerebral Stereotactic Instruments (Withdrawn 2017)
$17.4
ASTM F1266-89(2002)
Published Date: 01/01/2002
Standard Performance Specification for Cerebral Stereotactic Instruments
$17.4
ASTM F1266-89(1998)
Published Date: 01/01/1998
Standard Performance Specification for Cerebral Stereotactic Instruments
$18.6

Related products

ASTM F982-86(2008)
Published Date: 02/01/2008
Standard Specification for Disclosure of Characteristics of Surgically Implanted Clamps for Carotid Occlusion (Withdrawn 2017)
$15
ASTM F1328-00
Published Date: 10/10/2000
Standard Guide for Training Emergency Medical Technician (Basic) to Prepare Patients for Medical Transportation (Withdrawn 2006)
$15
ASTM F1622-95(2000)
Published Date: 01/01/2000
Test Method for Measuring the Torsional Properties of Metallic Bone Screws (Withdrawn 2001)
$15
ASTM F1978-22
Published Date: 10/01/2022
Standard Test Method for Measuring Abrasion Resistance of Metallic Thermal Spray Coatings by Using the Taber Abraser
$17.1

Best-Selling Products

DOXPUB 02-0001-SOP
Published Date: 08/01/2007
Recovery of Cryopreserved Cells
DOXPUB 02-0002-SOP
Published Date: 08/01/2007
Removal of Adherent Cells from Tissue Culture Flasks Using Trypsin/EDTA Solution
$4.2
DOXPUB 02-0003-SOP
Published Date: 08/01/2007
Assembly, Standardization, Sterilization and Inoculation of the Cell-Pharm Hollow Fiber Bioreactor for Antibody Production
$20.7
DOXPUB 02-0006-SOP-1.0
Published Date: 11/01/2004
Concentration of Bulk Antibody
$60
DOXPUB 02-0006-SOP
Published Date: 08/01/2007
Concentration of Bulk Antibody
$14.7
DOXPUB 02-0007-SOP
Published Date: 08/01/2007
Cell Culture Fluid Waste Disposal
$5.7