ASTM F1741-18 PDF

ASTM F1741-18 PDF

Name:
ASTM F1741-18 PDF

Published Date:
04/01/2018

Status:
Active

Description:

Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-f1741-18_2019326

Choose Document Language:
20.40 €
Need Help?

1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits for existing pipelines 6 to 180 in. in diameter by the insertion of a machine-made field-fabricated spiral wound liner pipe into the existing pipeline using a winding machine which remains stationary in the insertion pit or, alternatively, which travels along the interior of the existing pipeline. These rehabilitation processes can be used in a variety of gravity applications such as sanitary sewers, storm sewers, culverts, and process piping.

1.1.1 When using stationary installation equipment for existing pipelines 6 to 48 in., after insertion, the spiral wound liner pipe is expanded until it presses against the interior surface of the existing pipeline. Alternatively, for existing pipelines 6 to 108 in. in diameter, the spiral wound liner pipe is inserted as a fixed diameter into the existing pipeline and is not expanded, and the annular space between the spiral wound liner pipe and the existing pipe is grouted.

1.1.2 When using the traveling installation equipment for existing pipelines 6 to 180 in. the spiral wound liner pipe is installed in contact with the interior surface of the existing pipeline to form a close fit liner, except in the corners of rectangular pipes or where obstructions or offsets occur. Alternatively, for existing pipelines 6 to 180 in. in diameter and for similar sized existing non circular pipelines such as arched or oval or rectangular shapes, the spiral wound liner is installed as a fixed diameter into the exiting pipeline to form a non-close fit liner and the annular space between the spiral wound liner pipe and the existing pipe is grouted.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.3.1 Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 450 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 9
Published : 04/01/2018
Redline File Size : 2 files , 830 KB

History

ASTM F1741-22
Published Date: 11/15/2022
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.10 €
ASTM F1741-18
Published Date: 04/01/2018
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
20.40 €
ASTM F1741-08
Published Date: 11/01/2008
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €
ASTM F1741-07
Published Date: 06/01/2007
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €
ASTM F1741-05
Published Date: 08/15/2005
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €
ASTM F1741-02ae1
Published Date: 09/10/2002
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €
ASTM F1741-02a
Published Date: 09/10/2002
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €
ASTM F1741-02
Published Date: 01/10/2002
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €
ASTM F1741-96
Published Date: 01/10/2002
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
18.60 €
ASTM F1741-01e1
Published Date: 01/01/2001
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €
ASTM F1741-01
Published Date: 01/01/2001
Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
17.40 €

Related products

ASTM F810-12(2024)
Published Date: 06/01/2024
Standard Specification for Smoothwall Polyethylene (PE) Pipe for Use in Drainage and Waste Disposal Absorption Fields
16.50 €
ASTM D2104-03
Published Date: 08/10/2003
Standard Specification for Polyethylene (PE) Plastic Pipe, Schedule 40 (Withdrawn 2010)
18.00 €
ASTM F1947-21a
Published Date: 08/01/2021
Standard Practice for Installation of Folded Poly(Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits
15.60 €
ASTM F1807-23
Published Date: 02/01/2023
Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring, or Alternate Stainless Steel Clamps, for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
17.10 €

Best-Selling Products

BS CISPR 12:1997
Published Date: 04/15/1999
Vehicles, motorboats and spark-ignited engine-driven devices. Radio disturbance characteristics. Limits and methods of measurement
105.16 €
BS CISPR 16-1:1998
Published Date: 12/15/1998
Specification for radio disturbance and immunity measuring apparatus and methods-Radio disturbance and immunity measuring apparatus
119.63 €
BS CISPR 16-1:1999
Published Date: 10/08/2003
Specification for radio disturbance and immunity measuring apparatus and methods-Radio disturbance and immunity measuring apparatus
119.63 €
BS CISPR 16-2:1996
Published Date: 03/26/2003
Specification for radio disturbance and immunity measuring apparatus and methods-Methods of measurement of disturbances and immunity
119.63 €
BS CISPR 16-3:2000
Published Date: 09/15/2000
Specification for radio disturbance and immunity measuring apparatus and methods-Reports and recommendations of CISPR
119.63 €
CISPR 10 Amd.1 Ed. 4.0 b:1995
Published Date: 04/28/1995
Amendment 1 - Organization, rules and procedures of the CISPR
7.50 €