ASTM F1802-04(2010) PDF

ASTM F1802-04(2010) PDF

Name:
ASTM F1802-04(2010) PDF

Published Date:
08/01/2010

Status:
Active

Description:

Standard Test Method for Performance Testing of Excess Flow Valves

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$17.4
Need Help?

1.1 This test method covers a standardized method to determine the performance of excess flow valves (EFVs) designed to limit flow or stop flow in thermoplastic natural gas service lines.

1.2 All tests are intended to be performed using air as the test fluid. Unless otherwise stated, all flow rates are reported in standard cubic feet per hour of 0.6 relative density natural gas.

1.3 The test method recognizes two types of EFV. One type, an excess flow valve-bypass (EFVB), allows a small amount of gas to bleed through (bypass) after it has tripped, usually as a means of automatically resetting the device. The second type, an excess flow valve-non bypass (EFVNB), is intended to trip shut forming an essentially gas tight seal.

1.4 The performance characteristics covered in this test method include flow at trip point, pressure drop across the EFV, bypass flow rate of the EFVB or leak rate through the EFVNB after trip, and verification that the EFV can be reset.

1.4.1 Gas distribution systems may contain condensates and particulates such as organic matter, sand, dirt, and iron compounds. Field experience has shown that the operating characteristics of some EFVs may be affected by accumulations of these materials. The tests of Section 11 were developed to provide a simple, inexpensive, reproducible test that quantifies the effect, if any, of a uniform coating of kerosene and of kerosene contaminated with a specified amount of ferric oxide powder on an EFV's operating characteristics.

1.5 Excess flow valves covered by this test method will normally have the following characteristics: a pressure rating of up to 125 psig (0.86 MPa); a trip flow of between 200 and 2500 ft³/h (5.66 and 70.8 m³/h) at 10 psig (0.07 MPa); a minimum temperature rating of 0°F(-18°C), and a maximum temperature rating of 100°F (38°C).

1.6 The EFVs covered by this test method shall be constructed to fit piping systems no smaller than 1/2CTS and no larger than 11/4IPS, including both pipe and tubing sizes.

1.7 Tests will be performed at 67 ± 10°F (19.4 ± 5.5°C). Alternative optional test temperatures are 100 ± 10°F (37.7 ± 5.5°C) and 0 ± 10°F (-18 ± 5.5°C). All flow rates must be corrected to standard conditions.

1.8 This test method was written for EFVs installed in thermoplastic piping systems. However, it is expected that the test method may also be used for similar devices in other piping systems.

1.9 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautions, see Section 8.


File Size : 1 file , 130 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 7
Published : 08/01/2010

History

ASTM F1802-22
Published Date: 02/01/2022
Standard Test Method for Performance Testing of Excess Flow Valves
$16.2
ASTM F1802-04(2010)
Published Date: 08/01/2010
Standard Test Method for Performance Testing of Excess Flow Valves
$17.4
ASTM F1802-04
Published Date: 04/01/2004
Standard Test Method for Performance Testing of Excess Flow Valves
$17.4
ASTM F1802-97
Published Date: 05/10/1997
Standard Test Method for Performance Testing of Excess Flow Valves
$17.4

Related products

ASTM D3679-24
Published Date: 04/01/2024
Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Siding
$20.7
ASTM F948-94(2011)
Published Date: 08/01/2011
Standard Test Method for Time-to-Failure of Plastic Piping Systems and Components Under Constant Internal Pressure With Flow (Withdrawn 2018)
$18.6
ASTM F512-19(2024)
Published Date: 01/15/2024
Standard Specification for Smooth-Wall Poly(Vinyl Chloride) (PVC) Conduit and Fittings for Underground Installation
$18.9
ASTM F1960-24
Published Date: 07/01/2024
Standard Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing
$18.9

Best-Selling Products

B11 B11.0-2010
Published Date: 12/02/2010
Safety of Machinery; General Requirements and Risk Assessment
B11 B11.0-2020
Published Date: 12/16/2019
Safety of Machinery
B11 B11.0-2023
Published Date: 06/27/2023
Safety of Machinery
$71.7
B11 B11.1-2001
Published Date: 01/01/2001
Safety Requirements for Mechanical Power Presses
B11 B11.1-2009 (R2020)
Published Date: 04/07/2009
Safety Requirements for Mechanical Power Presses
$29.7
B11 B11.10-2003 (R2015)
Published Date: 08/26/2003
Safety Requirements for Metal Sawing Machines
$23.7